Towards comparable quality-assured Azure Kinect body tracking results in a study setting—Influence of light
Open Access
- 9 August 2024
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (8) , e0308416
Abstract
Quality assurance in research helps to ensure reliability and comparable results within a study. This includes reliable measurement equipment and data-processing. The Azure Kinect DK is a popular sensor used in studies with human subjects that tracks numerous joint positions with the Azure Kinect Body Tracking SDK. Prior experiments in literature indicate that light might influence the results of the body tracking. As similar light conditions are not always given in study protocols, the impact needs to be analyzed to ensure comparable results. We ran two experiments, one with four different light conditions and one with repeated measures of similar light conditions, and compared the results by calculating the random error of depth measurement, the mean distance error of the detected joint positions, and the distance between left and right ankle. The results showed that recordings with similar light conditions produce comparable results, with a maximum difference in the median value of mean distance error of 0.06 mm, while different light conditions result in inconsistent outcomes with a difference in the median value of mean distance error of up to 0.35 mm. Therefore, light might have an influence on the Azure Kinect and its body tracking. Especially additional infrared light appears to have a negative impact on the results. Therefore, we recommend recording various videos in a study under similar light conditions whenever possible, and avoiding additional sources of infrared light.Keywords
Funding Information
- Bundesministerium für Forschung, Technologie und Raumfahrt (01GY2021)
- Deutsche Forschungsgemeinschaft (456732630)
- Volkswagen Foundation (11-76251-12-10/19 ZN3491)
This publication has 19 references indexed in Scilit:
- Sentinel fall presenting to the emergency department (SeFallED) – protocol of a complex study including long-term observation of functional trajectories after a fall, exploration of specific fall risk factors, and patients’ views on falls preventionBMC Geriatrics, 2022
- GMH-D: Combining Google MediaPipe and RGB-Depth Cameras for Hand Motor Skills Remote Assessment2022
- Comparison of Azure Kinect overground gait spatiotemporal parameters to marker based optical motion captureGait & Posture, 2022
- Gait Analysis based on Azure Kinect 3D Human Skeleton2021
- Performance Analysis of Body Tracking with the Microsoft Azure Kinect2021
- Effects of camera viewing angles on tracking kinematic gait patterns using Azure Kinect, Kinect v2 and Orbbec Astra Pro v2Gait & Posture, 2021
- Step width variability as a discriminator of age-related gait changesJournal of NeuroEngineering and Rehabilitation, 2020
- IMpixel 65nm BSI 320MHz demodulated TOF Image sensor with 3μm global shutter pixels and analog binning2018
- Analysis of accuracy in optical motion capture – A protocol for laboratory setup evaluationJournal of Biomechanics, 2016
- Meaningful change in measures of gait variability in older adultsGait & Posture, 2010