Improvement in volume estimation from confocal sections after image deconvolution
- 1 June 2004
- journal article
- research article
- Published by Wiley in Microscopy Research and Technique
- Vol. 64 (2) , 151-155
Abstract
The confocal microscope can image a specimen in its natural environment forming a 3D image of the whole structure by scanning it and collecting light through a small aperture (pinhole), allowing in vivo and in vitro observations. So far, the confocal fluorescence microscope (CFM) is considered a true volume imager because of the role of the pinhole that rejects information coming from out‐of‐focus planes. Unfortunately, intrinsic imaging properties of the optical scheme presently employed yield a corrupted image that can hamper quantitative analysis of successive image planes. By a post‐image collection restoration, it is possible to obtain an estimate, with respect to a given optimization criterium, of the true object, utilizing the impulse response of system or Point Spread Function (PSF). The PSF can be measured or predicted so as to have a mathematical and physical model of the image‐formation process. Further modelling and recording noise as an additive Gaussian process has used the regularized Iterative Constrained Tykhonov Miller (ICTM) restoration algorithm for solving the inverse problem. This algorithm finds the best estimate iteratively searching among the possible positive solutions; in the Fourier domain, such an approach is relatively fast and elegant. In order to compare the effective improvement in the quantitative image information analysis, we measured the volume of reference objects before and after image restoration, using the isotropic Fakir method. Microsc. Res. Tech. 64:151–155, 2004.Keywords
This publication has 9 references indexed in Scilit:
- Influence of refractive-index mismatch in high-resolution three-dimensional confocal microscopyApplied Optics, 2002
- Confocal microscopy and stereology: Estimating volume, number, surface area and length by virtual test probes applied to three‐dimensional imagesMicroscopy Research and Technique, 2001
- Single-pinhole confocal imaging of sub-resolution sparse objects using experimental point spread function and image restorationMicroscopy Research and Technique, 2000
- Advantages of stereological methods in biomedicine. Efficiently obtaining unbiased estimates of geometrical characteristics for 3-D structuresIEEE Engineering in Medicine and Biology Magazine, 1998
- Introduction to Inverse Problems in Imaging1998
- Handbook of Biological Confocal Microscopy1995
- Lens Aberrations in Confocal Fluorescence Microscopy1995
- Aberrations in confocal fluorescence microscopy induced by mismatches in refractive indexJournal of Microscopy, 1993
- Spermiogenesis of Eledone cirrhosa Lamarck (Cephalopoda, Octopoda)Proceedings of the Royal Society of London. B. Biological Sciences, 1974