Simultaneous determination of paracetamol and lornoxicam by RP-HPLC in bulk and tablet formulation
Open Access
- 1 January 2011
- journal article
- Published by Manuscript Technomedia LLP in Pharmaceutical Methods
- Vol. 2 (1) , 61-66
Abstract
Aim: The objective of the study was to develop simple RP-HPLC method for the simultaneous determination of paracetamol and lornoxicam without prior separation. Materials and Methods: In this method, Kromasil C8 (250 mm, 4.6 mm, 5 μm) column was used. The mobile phase used was methanol:phosphate buffer (60:40, v/v, pH 6.4), at flow rate of 1 ml min-1. UV detection was monitored at 302 nm. Results: Calibration graphs were established in the range of 1-150 μg ml-1 and 0.5-100 μg ml-1 for paracetamol and lornoxicam, respectively. The average retention time for paracetamol and lornoxicam was found to be 3.15 ± 0.03 min and 5.25 ± 0.06 min, respectively. The detection limit and quantitation limit for paracetamol are 0.19 μg ml-1 and 0.59 μg ml-1 and for lornoxicam 0.10 μg ml-1 and 0.31 μg mL-1, respectively. The intraday and interday precision expressed as percent relative standard deviation were below 2%. The mean recovery of paracetamol and lornoxicam was found to be in the range of 99.03-101.2%. Conclusion: The validated HPLC method was found to be rapid, precise and accurate and can be readily utilized for analysis of paracetamol and lornoxicam in bulk and in pharmaceutical formulations. Key words: HPLC, lornoxicam, paracetamol, simultaneous determination, validation.Keywords
This publication has 21 references indexed in Scilit:
- Stability-Indicating LC Method for Analysis of Lornoxicam in the Dosage FormChromatographia, 2009
- A Selective and Sensitive Method for Simultaneous Determination of Traces of Paracetamol and p‐Aminophenol in Pharmaceuticals Using Carbon Ionic Liquid ElectrodeElectroanalysis, 2008
- Liquid chromatography-electrospray lonization tandem mass spectrometric determination of lornoxicam in human plasmaArchives of Pharmacal Research, 2007
- Method development and validation for the simultaneous determination of cetirizine dihydrochloride, paracetamol, and phenylpropanolamine hydrochloride in tablets by capillary zone electrophoresisJournal of Pharmaceutical and Biomedical Analysis, 2007
- Multicommuted flow system employing pinch solenoid valves and micro-pumpsJournal of Pharmaceutical and Biomedical Analysis, 2006
- Direct determination of paracetamol in powdered pharmaceutical samples by fluorescence spectroscopyAnalytica Chimica Acta, 2005
- Selective spectrofluorimetric method for paracetamol determination through coumarinic compound formationTalanta, 2005
- Semi-Micro Column HPLC of Three Oxicam Non-Steroidal Anti-Inflammatory Drugs in Human BloodBUNSEKI KAGAKU, 2005
- Square-Wave Adsorptive Stripping Voltammetric Determination of the Anti-Inflammatory Drug LornoxicamAnalytical Sciences, 2002
- LornoxicamDrugs, 1996