Small-Disturbance Stability of a Wind Farm With Virtual Synchronous Generators Under the Condition of Weak Grid Connection
- 17 May 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 36 (6) , 5500-5511
Abstract
Case-by-case study in the literature has found from the results of numerical computation and simulation that a grid-connected virtual synchronous generator (VSG) can maintain the stability under the condition of extremely weak grid connection. This paper presents the theoretical proof to the finding and thus, generally concludes that the grid-connected VSG is immune to the instability risk under the condition of weak grid connection. In addition, the paper extends the theoretical proof to the case of a grid-connected PMSG wind farm with multiple VSGs. An example grid-connected PMSG wind farm with twenty VSGs is presented to demonstrate and evaluate the theoretical analysis and conclusion made in the paper.Keywords
Funding Information
- Engineering Special Team of Sichuan University
- New Energy Power Systems
- National Natural Science Foundation of China (52077144)
This publication has 32 references indexed in Scilit:
- Impedance Analysis of Virtual Synchronous Generator-Based Vector Controlled Converters for Weak AC Grid IntegrationIEEE Transactions on Sustainable Energy, 2019
- Sequence Impedance Modeling and Stability Comparative Analysis of Voltage-Controlled VSGs and Current-Controlled VSGsIEEE Transactions on Industrial Electronics, 2018
- A Coordinated Control Scheme to Realize Frequency Support of PMSG-Based Wind Turbines in Weak Grids2018
- Wind in Weak Grids: 4 Hz or 30 Hz Oscillations?IEEE Transactions on Power Systems, 2018
- Sequence-Impedance-Based Stability Comparison Between VSGs and Traditional Grid-Connected InvertersIEEE Transactions on Power Electronics, 2018
- Resonance Mitigation of VSG Control under Weak-Grid Connected Microgrid2018
- An Oscillatory Stability Criterion Based on the Unified $dq$ -Frame Impedance Network Model for Power Systems With High-Penetration RenewablesIEEE Transactions on Power Systems, 2018
- Generalized short circuit ratio for multi-infeed LCC-HVDC systems2017
- An Explanation of Oscillations Due to Wind Power Plants Weak Grid InterconnectionIEEE Transactions on Sustainable Energy, 2017
- Virtual Synchronous Control for Grid-Connected DFIG-Based Wind TurbinesIEEE Journal of Emerging and Selected Topics in Power Electronics, 2015