Biomechanical study of the fixation stability of broken pedicle screws and subsequent strategies
Authors:
Open Access
- 28 June 2019
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (6) , e0219189
Abstract
Pedicles are often broken when screws are inserted into hard pedicles with small diameters or when the diameter of the screw itself is inadequate. However, there is a lack of biomechanical literature that addresses screw loosening as a result of broken pedicles or the resulting salvage of those screws. We performed a novel in vitro study to compare the pullout strength of screws between intact pedicles and two different types of broken pedicles; strategies to prevent screw loosening were also compared. Thirty L4 Sawbones were designed to represent intact pedicles, semi-pedicles, and nonpedicles and were prepared for screw insertion. Three sizes of polyaxial screws (diameter × length dimensions of 6.0 mm × 45 mm, 6.0 mm × 50 mm and 6.5 mm × 45 mm) were independently and randomly distributed into the intact-pedicle group (IP group, n = 30), the semi-pedicle group (SP group, n = 15), or the nonpedicle group (NP group, n = 15). The experiments were conducted across a minimum of five trials for each of the chosen screw sizes. We then analyzed the results of the imaging, pullout testing, and embedded bone volume. Any fractures or defects of the vertebrae caused by screw insertion were excluded from the study. The appropriate screw trajectory and insertional depth were confirmed using axial and sagittal X-ray imaging prior to screw pullout testing. A pullout strength of only 41% to 45% for the SP group and 29% to 39% for the NP group was retained following a broken pedicle. The use of longer or larger-diameter screws appears to be an effective salvaging procedure for the NP group (p < 0.05). The embedded bone volume percentage analysis indicated that, compared to the IP group, 68% to 76% of effective bone embedded into the screw threads in the SP group, and 58% to 65% in the NP group. There was no direct correlation between the pullout strength and the embedded bone volume; however, less effective embedded bone volume was associated with lower pullout strength. This study describes the evolution of the well-established screw pullout test being applied to the broken pedicle Sawbone testing model. The pedicle plays an important role in determining the pullout strength of a screw. However, a salvage procedure that utilizes a longer or larger-diameter screw might be a reliable clinical approach to address broken pedicles.Keywords
Funding Information
- Chang Gung Memorial Hospital, Linkou (CRRPG3H0081)
- Chang Gung Memorial Hospital, Linkou (CMRPD2F0173)
This publication has 35 references indexed in Scilit:
- Minimally Invasive Spinal Arthrodesis in Osteoporotic Population Using a Cannulated and Fenestrated Augmented Screw: Technical Description and Clinical ExperienceMinimally Invasive Surgery, 2012
- Fenestrated pedicle screws for cement-augmented purchase in patients with bone softening: a review of 21 casesJournal of Orthopaedics and Traumatology, 2011
- Instrumented lumbar arthrodesis in elderly patients: prospective study using cannulated cemented pedicle screw instrumentationEuropean Spine Journal, 2011
- A titanium expandable pedicle screw improves initial pullout strength as compared with standard pedicle screwsThe Spine Journal, 2011
- Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: A comparative study between cannulated screws with cement injection and solid screws with cement pre-fillingBMC Musculoskeletal Disorders, 2011
- Yoga and disc degenerative disease in cervical and lumbar spine: an MR imaging-based case control studyEuropean Spine Journal, 2010
- Anatomy of large animal spines and its comparison to the human spine: a systematic reviewEuropean Spine Journal, 2009
- Polymethylmethacrylate-Augmented Screw Fixation for Stabilization of the Osteoporotic Spine : A Three-Year Follow-Up of 37 PatientsJournal of Korean Neurosurgical Society, 2009
- Effect of Micrometer-Scale Roughness of the Surface of Ti6Al4V Pedicle Screws in Vitro and in VivoJournal of Bone and Joint Surgery, 2008
- Transpedicular screw fixation in the thoracic and lumbar spine with a novel cannulated polyaxial screw systemMedical Devices: Evidence and Research, 2008