Design, Actuation, and Control of an MRI-Powered Untethered Robot for Wireless Capsule Endoscopy
- 14 June 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (3) , 6000-6007
Abstract
Magnetic resonance imaging (MRI)-powered magnetic robotics aims to convert clinical MR scanners into a remote robotic manipulation platform to provide an alternative approach for interventional MRI procedures. The presence of the main magnetic field ( B 0 ) inside of MRI systems imposes magnetic constraints. Because of this static and strong magnetic field, many magnetic actuation techniques to orient or rotate magnetic objects are not feasible under MRI. Therefore, the robot design and actuation methods should consider these constraints for the intended medical applications. A free-to-rotate robot design could be utilized under MRI for providing rotational motion with magnetic pulling. However, the coupled translation with rotation induces difficulty in control of these robots, especially for camera pointing towards capsule endoscopy. In this study, we present a wireless magnetic robot that exploits a surface contact to create a rotation around a contact point with minimal translation. The proposed robot is integrated with a camera and an on-board battery for endoscopy purposes. The robot's tuned density also allows three-dimensional (3D) navigation to visually scan the workspace. We also demonstrate the open- and closed-loop actuation and control performance to explore the range of pitch angles accomplishable and closed-loop feedback control accuracy by using visual feedback. The closed-loop control experiments have shown 0.19 ° of steady-state error with 1.9 seconds rise time and 20% overshoot. Thanks to the surface contact during orientation control, the worst-case undesired translation is found to be 6.7 mm. Such robot provides the first steps towards active capsule endoscopy actuated by MRI devices for combining physiological images from an MRI device and the auxiliary visual camera images via the capsule robot to diagnose certain diseases in the gastrointestinal (GI) tract.Keywords
Funding Information
- Max-Planck Society
This publication has 18 references indexed in Scilit:
- Simultaneous steering and imaging of magnetic particles using MRI toward delivery of therapeuticsScientific Reports, 2016
- Toward tissue penetration by MRI-powered millirobots using a self-assembled Gauss gun2015
- An MRI-powered and controlled actuator technology for tetherless robotic interventionsThe International Journal of Robotics Research, 2013
- Blinded nonrandomized comparative study of gastric examination with a magnetically guided capsule endoscope and standard videoendoscopeGastrointestinal Endoscopy, 2012
- MRI driven magnetic microswimmersBiomedical Microdevices, 2011
- MRI magnetic signature imaging, tracking and navigation for targeted micro/nano-capsule therapeutics2011
- Three-Dimensional Controlled Motion of a Microrobot using Magnetic GradientsAdvanced Robotics, 2011
- Theory of gradient coil design methods for magnetic resonance imagingConcepts in Magnetic Resonance Part A, 2010
- Steering of aggregating magnetic microparticles using propulsion gradients coils in an MRI ScannerMagnetic Resonance in Medicine, 2010
- Real-Time MRI-Based Control of a Ferromagnetic Core for Endovascular NavigationIEEE Transactions on Biomedical Engineering, 2008