Evaluation of the effectiveness of near-infrared autofluorescence (NIRAF) imaging combined with immunocolloidal gold technique (ICGT) in identifying and protecting parathyroid glands during thyroid cancer surgery
Open Access
- 1 August 2025
- journal article
- Published by AME Publishing Company in Gland Surgery
- Vol. 14 (8) , 1519-1528
Abstract
Background: The hypocalcemia and hypoparathyroidism due to parathyroid damage during thyroid cancer surgery seriously affect the quality of life of patients. Although contemporary scholars have implemented different technologies, demonstrating improved intraoperative outcomes, there is still a lack of reliable real-time recognition technology. The aim of this study is to assess the efficacy of near-infrared autofluorescence (NIRAF) imaging combined with immunocolloidal gold technique (ICGT) in identifying and protecting parathyroid glands (PTGs) during thyroid cancer surgery. Methods: This retrospective cohort study evaluated 62 thyroid cancer patients undergoing total thyroidectomy with bilateral central lymph node dissection (CLND) by the same surgical team (January–December 2023). Cohort allocation was based on intraoperative identification methods: the observation group (n=34) received NIRAF and ICGT, while the control group (n=28) underwent standard visual assessment. Primary endpoints included (I) intraoperative parathyroid detection quantitation; (II) rates of in situ gland preservation vs. autotransplantation; and (III) incidence of unintended parathyroid resection. Secondary outcomes assessed postoperative biochemical profiles [parathyroid hormone (PTH) and calcium levels at 24/72 h] and surgical complications. All statistical comparisons were performed with SPSS version 27.0. Results: Intraoperative analysis demonstrated superior glandular preservation in the NIRAF-ICGT cohort, with 128/132 (97.0%) PTGs maintained in situ versus 83/97 (85.6%) in conventional controls (P0.05), immediate postoperative metrics revealed substantial physiological advantages. Biochemical monitoring at 24 h postoperatively showed higher calcium levels in the observation group (2.11±0.13 vs. 1.94±0.10 mmol/L, P vs. 10.50 [3.70] pg/mL, P vs. 2.08±0.11 mmol/L, P vs. 14.32 (IQR 2.08) pg/mL, P vs. 18 cases) and lower transient hypoparathyroidism rates (10 vs. 16 case), both PConclusions: Compared to traditional visual recognition, the NIRAF-ICGT integrated technology can help surgeons better identify and protect parathyroid function during thyroid cancer surgery.Keywords
This publication has 24 references indexed in Scilit:
- Diseased thyroid tissue classification inOCTimages using deep learning: Towards surgical decision supportJournal of Biophotonics, 2022
- Indocyanine green fluorescence and near-infrared autofluorescence may improve post-thyroidectomy parathyroid functionSurgery, 2022
- The Role of Carbon Nanoparticles in Lymph Node Dissection and Parathyroid Gland Preservation during Surgery for Thyroid Cancer: A Systematic Review and Meta-AnalysisCancers, 2022
- Ex vivo hypercellular parathyroid gland differentiation using dynamic optical contrast imaging (DOCI)Biomedical Optics Express, 2022
- Postoperative hypoparathyroidism after completion thyroidectomy for well-differentiated thyroid cancerEuropean Journal of Endocrinology, 2021
- A Rapid Intraoperative Parathyroid Hormone Assay Based on the Immune Colloidal Gold Technique for Parathyroid Identification in Thyroid SurgeryFrontiers in Endocrinology, 2021
- What are the real rates of temporary hypoparathyroidism following thyroidectomy? It is a matter of definition: a systematic reviewEndocrine, 2021
- Development of an imaging device for label‐free parathyroid gland identification and vascularity assessmentJournal of Biophotonics, 2021
- Surgical strategy when identifying less than four parathyroid glands during total thyroidectomy: a retrospective cohort studyGland Surgery, 2021
- Fine‐needle aspiration of parathyroid adenomas: Indications as a diagnostic approachDiagnostic Cytopathology, 2020