Energy balance in the semiarid area of the Loess Plateau, China
- 21 February 2017
- journal article
- research article
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 122 (4) , 2155-2168
Abstract
To understand the energy balance over the complex terrain of the Loess Plateau, we analyzed data from the Semi‐Arid Climate and Environment Observatory of Lanzhou University (SACOL). From 1 June to 15 August 2008, the energy balance closure ratio ranged from 0.52 to 0.90 during the daytime when the available energy was greater than 150 W m−2; during nocturnal hours, it was about 0.25. We proposed a method based on water mass conservation to estimate the energy transmitted by the vertical movement of moisture in the soil and set out to explain the imbalance. During the daytime, the heat stored in the soil above the heat flux plate placed at 5 cm below the surface, the energy transmitted by the vertical movement of moisture in the soil, and the energy assimilated by plant photosynthesis contributed to 29.6%, 2.0%, and 1.8% of the energy residual, respectively. During stable conditions, the soil heat storage contributed to 46.4% of the energy residual, whereas the other energy terms contributed little. The instantaneous energy closure ratio was about 0.80 during unstable conditions; it was about 0.40 when the wind speed U was greater than 3.0 m s−1, while depends systematically on U under condition of U < 3.0 m s−1 during stable conditions. Under the weak wind stable condition, affected by topography‐induced nonstationary motions, the turbulence is anisotropic with a strong horizontal fluctuation and a weak vertical fluctuation, resulting in weakened heat mixing in the vertical direction and stronger unclosure of energy.Keywords
Funding Information
- National Natural Science Foundation of China (41475008, 41605005)
- Chinese Academy of Sciences
This publication has 47 references indexed in Scilit:
- Energy balance closure for the LITFASS-2003 experimentTheoretical and Applied Climatology, 2009
- Characterisation of the Nocturnal Boundary Layer at a Site in Northern SpainBoundary-Layer Meteorology, 2008
- A Modelling Study of Flux Imbalance and the Influence of Entrainment in the Convective Boundary LayerBoundary-Layer Meteorology, 2007
- The Energy Balance Experiment EBEX-2000. Part I: overview and energy balanceBoundary-Layer Meteorology, 2007
- Flux contribution of coherent structures and its implications for the exchange of energy and matter in a tall spruce canopyBoundary-Layer Meteorology, 2007
- Surface energy balance measurements at a tropical site in West Africa during the transition from dry to wet seasonTheoretical and Applied Climatology, 2006
- The energy balance experiment EBEX-2000. Part II: Intercomparison of eddy-covariance sensors and post-field data processing methodsBoundary-Layer Meteorology, 2006
- Evaluation of six parameterization approaches for the ground heat fluxTheoretical and Applied Climatology, 2006
- Determination of soil heat flux in a tibetan short-grass prairieBoundary-Layer Meteorology, 2005
- Experimental determination of turbulent fluxes over the heterogeneous LITFASS area: Selected results from the LITFASS-98 experimentTheoretical and Applied Climatology, 2002