Comparison of Central Macular Thickness Measured by Three OCT Models and Study of Interoperator Variability
Open Access
- 1 January 2012
- journal article
- research article
- Published by Hindawi Limited in The Scientific World Journal
- Vol. 2012, 1-6
Abstract
Purpose. To compare central macular thickness (CMT) measurement on healthy patient using 3 different OCT devices by two operators.Methods. Prospective, monocentricstudy. Right eye’s central macular thickness (CMT) of 30 healthy patients has been measured three times using a time-domain (TD) OCT (Stratus OCT, Carl Zeiss Meditec, Dublin, Ca) and two spectral domain (SD) OCTs (Cirrus HD-OCT, Carl ZeissMeditec, Dublin, Ca) and 3D-OCT 1000 (Topcon, Tokyo, Japan) by two operators. Six measurements were taken randomly for each patient the same day.Results. No significant difference between measurements obtained by the two operators has been observed, whatever the studied OCT.Pvalue was 0.164, 0.193, and 0.147 for Stratus OCT, Cirrus HD-OCT and 3D-OCT, respectively. Mean CMT significantly differed from instrument to instrument () and was, respectively, 197 μm, 254 μm, and 236 μm using Stratus OCT, Cirrus HD-OCT, and 3D-OCT 1000. Using Cirrus OCT and 3D-OCT 1000, CMT was, respectively, 57 μm and 39 μm thicker than using Stratus OCT ().Conclusions. Whatever the OCT device, on healthy patients CMT was not operator dependent. CMT measurements obtained by SD-OCTs are greater than those obtained by TD-OCT. These data imply that the different OCT devices cannot be used interchangeably in clinical monitoring.
Keywords
This publication has 22 references indexed in Scilit:
- Reproducibility of Retinal Thickness Measurements on Normal and Pathologic Eyes by Different Optical Coherence Tomography InstrumentsAmerican Journal of Ophthalmology, 2010
- Macular Thickness Interoperator and Intraoperator Reproducibility in Healthy Eyes Using 7 Optical Coherence Tomography InstrumentsAmerican Journal of Ophthalmology, 2010
- Macular Thickness Measurements in Healthy Eyes Using Six Different Optical Coherence Tomography InstrumentsInvestigative Ophthalmology & Visual Science, 2009
- Comparison of retinal thickness measurements and segmentation performance of four different spectral and time domain OCT devices in neovascular age-related macular degenerationBritish Journal of Ophthalmology, 2009
- Comparison of Spectral- and Time-Domain Optical Coherence Tomography for Retinal Thickness Measurements in Healthy and Diseased EyesAmerican Journal of Ophthalmology, 2009
- Spectral and time domain OCT measure identical retinal thickness if identical boundaries are selected for analysisEye, 2009
- Comparison of Macular Thickness Between Cirrus HD-OCT and Stratus OCTOphthalmic Surgery, Lasers and Imaging Retina, 2009
- Prospective Comparison of Cirrus and Stratus Optical Coherence Tomography for Quantifying Retinal ThicknessAmerican Journal of Ophthalmology, 2009
- Tomographie par cohérence optique de type Spectral Domain dans la dégénérescence maculaire liée à l’âgeJournal Français d'Ophtalmologie, 2008
- Optical Coherence Tomography Findings in Diabetic Retinopathy2007