Aerobic Power and Capacity in Highly Trained National-Level Youth Soccer Players Through On-Field Gas Exchange Assessment in an Ecological Context: A Brief Report
Authors:
- Martin Fernando BruzzeseMBMartin Fernando Bruzzese
- Gastón César GarcíaGGGastón César García
- Carlos Rodolfo ArcuriCACarlos Rodolfo Arcuri
- Mauro Darío SantanderMSMauro Darío Santander
- Jeremías David SecchiJSJeremías David Secchi
- José Augusto Rodrigues dos SantosJosé Augusto Rodrigues dos Santos
- Rodrigo ZaccaRodrigo Zacca
Open Access
- 10 April 2025
- journal article
- research article
- Published by MDPI AG in Physiologia
- Vol. 5 (2) , 14
Abstract
Background: Extensive data exists on external load during training and competition, but a significant gap remains in understanding internal physiological load, particularly in protocols conducted in ecological settings. Given the scarcity of studies on the on-field cardiorespiratory profiles of national-level athletes, especially in Argentine soccer, this study aimed to identify the on-field cardiorespiratory fitness profile of ten highly trained youth field soccer players (13.6 ± 1.3 years old) from both the first league of the Argentine Football Association and members of the national team in their age group category in the current year. Methods: Each athlete performed an on-field cardiorespiratory exercise test (20-m Shuttle Run Test, 20-m SRT) with the COSMED K5 wearable metabolic system (COSMED, Rome, Italy) in dynamic micro-mixing chamber mode. The 20-m Shuttle Run Test involves running back and forth between two lines set 20 m apart, following the pace set by an audio signal. The test starts at a running velocity of 8.5 km·h−1 and increases by 0.5 km·h−1 each min. Results: Mean velocity at maximal oxygen uptake (vO2max) was 12.3 ± 0.7 km·h−1. The maximal oxygen uptake (O2max) on-field was 67.1 ± 5.3 mL·kg−1·min−1. The O2 at the first and second ventilatory thresholds (VT1 and VT2) were identified at 67.0 ± 3.0% O2max (44.9 ± 3.3 mL·kg−1·min−1) and 84.7 ± 3.7% O2max (56.8 ± 3.8 mL·kg−1·min−1), respectively. Conclusions: This is a scarce on-field gas exchange assessment, conducted in an ecological context using a portable analyzer with highly trained national-level youth soccer players from the Argentine youth national team, which underlines their cardiorespiratory fitness, showcases their high-performance potential, offers valuable insights into a selective group of players, and provides a reference for larger-scale research on elite youth soccer and the long-term development of aerobic power and capacity.
Keywords
Funding Information
- Fundação para a Ciência e Tecnologia (UIDB/00617/2020, UIDP/00617/2020)
This publication has 25 references indexed in Scilit:
- Reference values for maximum oxygen uptake relative to body mass in Dutch/Flemish subjects aged 6–65 years: the LowLands Fitness RegistryEuropean Journal of Applied Physiology, 2021
- Prediction of maturity offset and age at peak height velocity in a longitudinal series of boys and girlsAmerican Journal of Human Biology, 2020
- Test course navette de 20 metros con etapas de un minuto. Una idea original que perdura hace 30 añosApunts. Medicina de l'Esport, 2014
- Seguimiento longitudinal de la evolución en la condición aeróbica en jóvenes futbolistasApunts. Medicina de l'Esport, 2010
- Match Running Performance and Fitness in Youth SoccerInternational Journal of Sports Medicine, 2010
- Artificial neural network-based equation for estimating VO2max from the 20 m shuttle run test in adolescentsArtificial Intelligence in Medicine, 2008
- Maximal oxygen uptake during field running does not exceed that measured during treadmill exerciseEuropean Journal of Applied Physiology, 2003
- Effects of High Intensity Intermittent Training on Peak V˙O2 in Prepubertal ChildrenInternational Journal of Sports Medicine, 2002
- The multistage 20 metre shuttle run test for aerobic fitnessJournal of Sports Sciences, 1988
- Work Activity and Coronary Heart MortalityNew England Journal of Medicine, 1975