Intra‐ and interobserver reliability of lens equatorial length measurement using 35‐MHz ultrasound biomicroscopy in dogs with cataract
- 13 August 2016
- journal article
- Published by Wiley in Veterinary Ophthalmology
- Vol. 20 (4) , 329-334
Abstract
Purpose: To determine intra‐ and interobserver reliability of lens equatorial length measurement using 35‐MHz ultrasound biomicroscopy in dogs with cataract.Methods: Ocular ultrasonography was performed on 28 dogs (50 eyes) before phacoemulsification. Lens equatorial length was measured on still images obtained at 35 MHz in all dogs. Each observer (A and B) obtained the measurements independently. Coefficients of variation (CVs) were used to assess intraobserver repeatability and interobserver reproducibility. Intraobserver repeatability was assessed by comparing measurements obtained on the same image on four different occasions by observer A. Interobserver reproducibility was assessed by comparing measurements obtained independently by both observers on the same image.Results: CV used to assess intraobserver repeatability was 2.4% with good agreement and no significant difference between repetitions (P> 0.05).CVused to assess interobserver reproducibility was 5.8% without significant difference between measurements obtained by the two observers (P> 0.05).Conclusions: Intraobserver repeatability and interobserver reproducibility were considered good for lens equatorial length measurement at 35 MHz in dogs with cataract. Ultrasound biomicroscopy could be an acceptable method to assess lens equatorial dimension before phacoemulsification and intraocular lens implantation in dogs with cataract.Keywords
This publication has 36 references indexed in Scilit:
- Effect of mydriasis induced by topical instillations of 0.5% tropicamide on the anterior segment in normotensive dogs using ultrasound biomicroscopyVeterinary Ophthalmology, 2011
- Relationship of the iridocorneal angle, as measured using ultrasound biomicroscopy, with post‐operative increases in intraocular pressure post‐phacoemulsification in dogsVeterinary Ophthalmology, 2009
- Evaluation of the relationship between corneal diameter and lens diameterJournal of Cataract & Refractive Surgery, 2008
- Ultrasound biomicroscopy of the iridocorneal angle of the eye before and after phacoemulsification and intraocular lens implantation in dogsAmerican Journal of Veterinary Research, 2008
- Direct Measurement of the Ciliary Sulcus Diameter by 35-Megahertz Ultrasound BiomicroscopyOphthalmology, 2007
- Keratometry, biometry and prediction of intraocular lens power in the equine eyeVeterinary Ophthalmology, 2006
- Lens morphometry determined by B‐mode ultrasonography of the normal and cataractous canine lensVeterinary Ophthalmology, 2004
- Basic concepts in statistics for veterinary ophthalmologistsVeterinary Ophthalmology, 2004
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Diagnostic Ultrasonography of the Dog Eye*Journal of Small Animal Practice, 1969