Abstract
We report clear observation of a high voltage (HV) threshold for stable operation in a dc electron gun. The HV hold-off time without any discharge is longer than many hours for operation below the threshold, while it is roughly 10 min above the threshold. The HV threshold corresponds to the minimum voltage where discharge ceases. The threshold increases with the number of discharges during HV conditioning of the gun. Above the threshold, the amount of gas desorption per discharge increases linearly with the voltage difference from the threshold. The present experimental observations can be explained by an avalanche discharge model based on the interplay between electron stimulated desorption (ESD) from the anode surface and subsequent secondary electron emission from the cathode by the impact of ionic components of the ESD molecules or atoms.Keywords
Funding Information
- JSPS Grant-in-Aid for Scientific Research in Japan (15H03594)
This publication has 15 references indexed in Scilit:
- Demonstration of cathode emittance dominated high bunch charge beams in a DC gun-based photoinjectorApplied Physics Letters, 2015
- Experimental investigation of an optimum configuration for a high-voltage photoemission gun for operation atPhysical Review Special Topics - Accelerators and Beams, 2014
- Growth and characterization of rugged sodium potassium antimonide photocathodes for high brilliance photoinjectorApplied Physics Letters, 2013
- Generation of a 500-keV electron beam from a high voltage photoemission gunApplied Physics Letters, 2013
- A Large Hadron Electron Collider at CERN Report on the Physics and Design Concepts for Machine and DetectorJournal of Physics G: Nuclear and Particle Physics, 2012
- High-voltage testing of a 500-kV dc photocathode electron gunReview of Scientific Instruments, 2010
- Reduction of field emission dark current for high-field gradient electron gun by using a molybdenum cathode and titanium anodeNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2005
- Titanium alloy material with very low outgassingJournal of Vacuum Science & Technology A, 2003
- Electron- and photon-induced desorptionJournal of Nuclear Materials, 1974
- Electron-Stimulated Desorption as a Tool for Studies of Chemisorption: A ReviewJournal of Vacuum Science and Technology, 1971