Differences in cardiac microcirculatory wave patterns between the proximal left mainstem and proximal right coronary artery
- 1 September 2008
- journal article
- research article
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 295 (3) , H1198-H1205
Abstract
Despite having almost identical origins and similar perfusion pressures, the flow-velocity waveforms in the left and right coronary arteries are strikingly different. We hypothesized that pressure differences originating from the distal (microcirculatory) bed would account for the differences in the flow-velocity waveform. We used wave intensity analysis to separate and quantify proximal- and distal-originating pressures to study the differences in velocity waveforms. In 20 subjects with unobstructed coronary arteries, sensor-tipped intra-arterial wires were used to measure simultaneous pressure and Doppler velocity in the proximal left main stem (LMS) and proximal right coronary artery (RCA). Proximal- and distal-originating waves were separated using wave intensity analysis, and differences in waves were examined in relation to structural and anatomic differences between the two arteries. Diastolic flow velocity was lower in the RCA than in the LMS (35.1 ± 21.4 vs. 56.4 ± 32.5 cm/s, P < 0.002), and, consequently, the diastolic-to-systolic ratio of peak flow velocity in the RCA was significantly less than in the LMS (1.00 ± 0.32 vs. 1.79 ± 0.48, P < 0.001). This was due to a lower distal-originating suction wave (8.2 ± 6.6 × 103 vs. 16.0 ± 12.2 × 103 W·m−2·s−1, P < 0.01). The suction wave in the LMS correlated positively with left ventricular pressure ( r = 0.6, P < 0.01) and in the RCA with estimated right ventricular systolic pressure ( r = 0.7, P = 0.05) but not with the respective diameter in these arteries. In contrast to the LMS, where coronary flow velocity was predominantly diastolic, in the proximal RCA coronary flow velocity was similar in systole and diastole. This difference was due to a smaller distal-originating suction wave in the RCA, which can be explained by differences in elastance and pressure generated between right and left ventricles.Keywords
This publication has 26 references indexed in Scilit:
- Effect of simultaneous intracoronary guidewires on the predictive accuracy of functional parameters of coronary lesion severityAmerican Journal of Physiology-Heart and Circulatory Physiology, 2007
- Wave dissipation in flexible tubes in the time domain: In vitro model of arterial wavesJournal of Biomechanics, 2007
- Evidence of a Dominant Backward-Propagating “Suction” Wave Responsible for Diastolic Coronary Filling in Humans, Attenuated in Left Ventricular HypertrophyCirculation, 2006
- Use of simultaneous pressure and velocity measurements to estimate arterial wave speed at a single site in humansAmerican Journal of Physiology-Heart and Circulatory Physiology, 2006
- Usefulness of a New Grading System Based on Coronary Flow Velocity Pattern in Predicting Outcome in Patients With Acute Myocardial Infarction Having Percutaneous Coronary InterventionThe American Journal of Cardiology, 2005
- Effects of left ventricular contractility and coronary vascular resistance on coronary dynamicsAmerican Journal of Physiology-Heart and Circulatory Physiology, 2004
- Differential characterization of blood flow, velocity, and vascular resistance between proximal and distal normal epicardial human coronary arteries: Analysis by intracoronary Doppler spectral flow velocityAmerican Heart Journal, 1995
- Velocity profiles and phasic flow patterns in the non-stenotic human left anterior descending coronary artery during cardiac surgeryCardiovascular Research, 1993
- Physiological hypotheses-Intramyocardial pressure. A new concept, suggestions for measurementBasic Research in Cardiology, 1990
- What stops the flow of blood from the heart?Heart and Vessels, 1988