Detection of Nonesterified (Free) Fatty Acids in Bovine Serum: Comparative Evaluation of Two Methods
Authors:
- 1 March 2004
- journal article
- research article
- Published by SAGE Publications in Journal of Veterinary Diagnostic Investigation
- Vol. 16 (2) , 139-144
Abstract
A method comparison study for the determination and quantitation of nonesterified fatty acids (NEFAs) in serum, using the commercial “NEFA C” enzymatic test kit, was performed using the spectrophotometric method recommended by the manufacturer and a modified procedure optimized for the use of a microplate reader, a 96-well microtiter plate, and small sample volumes (10 μl). Linearity, sensitivity, and precision using the test kit were determined for each method of detection. The assay was linear from 0 to 1.97 mEq/liter for both procedures, and the limits of detection were determined to be 0.22 (±0.074) and 0.05 (±0.002) mEq/liter for the spectrophotometer and microplate reader, respectively. Pairs of measurements for bovine serum samples were compared and evaluated by a mean difference plot method and not regression analysis, a method that has been shown to be inappropriate for method comparison studies. The difference plot was used to evaluate the systematic bias between the 2 methods. Random error is reported on the basis of SD differences, and “limits of agreement” are used to describe the maximum differences likely to occur between the 2 methods. Results suggest that the microplate reader method can be used reliably in place of the recommended spectrophotometric method. The microplate reader method is preferred because of its high throughput capabilities, simultaneous analysis of all the standards and samples, use of small sample and reagent volumes, and reduction in labor requirements and costs.Keywords
This publication has 34 references indexed in Scilit:
- Detection of bias in method comparison by regression analysisAnalytica Chimica Acta, 1997
- Determination of free fatty acids in blood, tagged with 4‐(2‐carbazoylpyrrolidin‐1‐yl)‐7‐(N, N‐dimethylaminosulfonyl)‐2, 1, 3‐benzoxadiazole, by high‐performance liquid chromatography with fluorescence detectionBiomedical Chromatography, 1995
- Methods for Separation of Free, Short, Medium, and Long Chain Fatty Acids and for Their DecarboxylationAnalytical Biochemistry, 1995
- Evaluating agreement between two methods for measuring the same quantity: A responseComputers in Biology and Medicine, 1992
- Enzymatic microdetermination of plasma and serum free fatty acidsScandinavian Journal of Clinical and Laboratory Investigation, 1992
- Separation and quantitation of plasma free fatty acids as phenacyl esters by HPLCBiomedical Chromatography, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Application of an automated enzymatic technique for the determination of non-esterified fatty acids in bovine bloodVeterinary Record, 1984
- Simultaneous separation and sensitive determination of free fatty acids in blood plasma by high-performance liquid chromatographyJournal of Chromatography B: Biomedical Sciences and Applications, 1984
- Determination of plasma non-esterified fatty acids in herbivores and man : a comparison of values obtained by manual or automatic chromatographic, titrimetric, colorimetric and enzymatic methodsReproduction Nutrition Développement, 1984