Electro-Optical Performance Study of 4H-SiC/Pd Schottky UV Photodetector Array for Space Applications
- 3 July 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 67 (8) , 3242-3249
Abstract
4H-SiC Schottky photodetector array was fabricated by pulsed dc sputter deposition of palladium thin film as UV semitransparent Schottky contact on active pixel. Results of electro-optical characterization of these devices as a function of temperature varying from 33 to 393 K are presented. A peak spectral responsivity of 122 mAW −1 at 280 nm is observed. Further, spatial response uniformity for a 4 mm $\times4$ mm detector, scanned by UV spot of $100~\mu \text{m}$ diameter, is within ±5%, whereas the crosstalk between the pixels in $4\times 2$ detector array with a pixel size of $850\,\,\mu \text{m}\,\,\times 850\,\,\mu \text{m}$ is within 1.3%. Capacitance at near zero bias is around 11 pF and 4.79 pF at a reverse bias of 30 V. From the ${I}$ – ${V}$ characteristics, the calculated Schottky barrier height is 1.37 eV for 70 Å thick palladium metal film on 4H-SiC as against the theoretical value of 1.96 eV. Operating temperature studies on detector UV response at 300 nm have shown that the photo-current response at 113 K falls to half of its peak value at ambient. The responsivity of the detectors at 248-nm wavelength is almost constant over a wide temperature range of 33 to 393 K.Keywords
This publication has 24 references indexed in Scilit:
- High quantum efficiency deep ultraviolet 4H‐SiC photodetectorsElectronics Letters, 2013
- A Comprehensive Review of Semiconductor Ultraviolet Photodetectors: From Thin Film to One-Dimensional NanostructuresSensors, 2013
- The Space Weather and Ultraviolet Solar Variability (SWUSV) Microsatellite MissionJournal of Advanced Research, 2013
- 4H–SiC Metal–Semiconductor–Metal Ultraviolet Photodetectors in Operation of 450 $^{\circ}\hbox{C}$IEEE Electron Device Letters, 2012
- REMS: The Environmental Sensor Suite for the Mars Science Laboratory RoverSpace Science Reviews, 2012
- R3DE: Radiation Risk Radiometer-Dosimeter on the International Space Station—Optical Radiation Data Recorded During 18 Months of EXPOSE-E Exposure to Open SpaceAstrobiology, 2012
- SiC sensors: a reviewJournal of Physics D: Applied Physics, 2007
- Temperature stable Pd ohmic contacts to p-type 4H-SiC formed at low temperaturesIEEE Transactions on Electron Devices, 1999
- Semiconductor ultraviolet detectorsJournal of Applied Physics, 1996
- Extraction of Schottky diode parameters from forward current-voltage characteristicsApplied Physics Letters, 1986