A Custom-Made Lower Limb Dynamometer for Assessing Ankle Joint Torque in Humans: Calibration and Measurement Procedures
Authors:
- Iulia Iovanca DrăgoiIDIulia Iovanca Drăgoi
- Florina Georgeta PopescuFPFlorina Georgeta Popescu
- Teodor PetrițaTPTeodor Petrița
- Romulus Fabian TatuRTRomulus Fabian Tatu
- Cosmina Ioana BondorCBCosmina Ioana Bondor
- Carmen TatuCTCarmen Tatu
- Frank L. BowlingFBFrank L. Bowling
- Neil D. ReevesNRNeil D. Reeves
- Mihai IonacMIMihai Ionac
Open Access
Abstract
Custom-made dynamometry was shown to objectively analyze human muscle strength around the ankle joint with accuracy, easy portability and low costs. This paper describes the full method of calibration and measurement setup and the measurement procedure when capturing ankle torque for establishing reliability of a portable custom-built electronic dynamometer. After considering the load cell offset voltage, the pivotal position was determined, and calibration with loads followed. Linear regression was used for calculating the proportionality constant between torque and measured voltage. Digital means were used for data collection and processing. Four healthy consenting participants were enrolled in the study. Three consecutive maximum voluntary isometric contractions of five seconds each were registered for both feet during plantar flexion/dorsiflexion, and ankle torque was then calculated for three ankle inclinations. A calibration procedure resulted, comprising determination of the pivotal axis and pedal constant. Using the obtained data, a measurement procedure was proposed. Obtained contraction time graphs led to easier filtering of the results. When calculating the interclass correlation, the portable apparatus demonstrated to be reliable when measuring ankle torque. When a custom-made dynamometer was used for capturing ankle torque, accuracy of the method was assured by a rigorous calibration and measurement protocol elaboration.Keywords
This publication has 12 references indexed in Scilit:
- Knee and Ankle Joint Angles Influence the Plantarflexion Torque of the GastrocnemiusJournal of Clinical Medicine Research, 2015
- Ankle dorsi- and plantar-flexion torques measured by dynamometry in healthy subjects from 5 to 80 yearsBMC Musculoskeletal Disorders, 2013
- The potential of human toe flexor muscles to produce forceJournal of Anatomy, 2012
- Importance and challenges of measuring intrinsic foot muscle strengthJournal of Foot and Ankle Research, 2012
- Muscle and Joint Function in Human LocomotionAnnual Review of Biomedical Engineering, 2010
- Development of a French Isometric Strength Normative Database for Adults Using Quantitative Muscle TestingArchives of Physical Medicine and Rehabilitation, 2007
- Maximum voluntary isometric contraction: Reference values and clinical applicationAmyotrophic Lateral Sclerosis, 2007
- Isometric Muscle Torque in Children 5 to 15 Years of Age: Normative DataArchives of Physical Medicine and Rehabilitation, 2006
- Influence of 90-day simulated microgravity on human tendon mechanical properties and the effect of resistive countermeasuresJournal of Applied Physiology, 2005
- Isokinetic Muscle Testing: Is It Clinically Useful?Journal of the American Academy of Orthopaedic Surgeons, 1994