Ion Mobility Studies on the Negative Ion-Molecule Chemistry of Isoflurane and Enflurane
Open Access
- 21 February 2017
- journal article
- research article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 28 (5) , 939-946
Abstract
In the present work we present an investigation of the negative ion-molecule chemistry of the anaesthetics isoflurane, ISOF, and enflurane, ENF, in an ion mobility spectrometry/mass spectrometry (IMS/MS), in both air and nitrogen. Hexachloroethane (HCE) was introduced in both air and nitrogen to produce Cl– as a reactant ion. This study was undertaken owing to uncertainties in the chemical processes, which lead to the cluster ions reported in other work (Eiceman et al. Anal. Chem. 61, 1093–1099, 1 ). In particular for ISOF the product ion observed was ISOF.Cl–, and it was suggested that the Cl– was formed by dissociative electron attachment (DEA) although there was mention of a chlorine containing contaminant. We show in this study that ISOF and ENF do not produce Cl– in an IMS system either by capture of free electrons or reaction with O2 –. This demonstrates that the Cl– containing ions, reported in the earlier study, must have been the result of a chlorine containing contaminant as suggested. The failure of ISOF and ENF to undergo DEA was initially surprising given the high calculated electron affinities, but further calculations showed that this was a result of the large positive vertical attachment energies (VAEs). This experimental work has been supported by electronic structure calculations at the B3LYP level, and is consistent with those obtained in a crossed electron-molecular beam two sector field mass spectrometer. An unusual observation is that the monomer complexes of ISOF and ENF with O2 – are relatively unstable compared with the dimer complexes.Keywords
Funding Information
- Seventh Framework Programme (287382)
This publication has 18 references indexed in Scilit:
- A Novel Pulsed Doping Method for Enhancing the Sensitivity of Ion Mobility Spectrum (IMS) for Detecting Explosives and a Mechanism StudySensor Letters, 2015
- Gas phase ion chemistry of an ion mobility spectrometry based explosive trace detector elucidated by tandem mass spectrometryTalanta, 2015
- Ion Mobility Spectrometry2013
- Ion mobility spectrometers with doped gasesTalanta, 2008
- A critical review of ion mobility spectrometry for the detection of explosives and explosive related compoundsTalanta, 2001
- An investigation of electron attachment to CHCl2F, CHClF2 and CHF3 using an electron-swarm mass spectrometric techniqueInternational Journal of Mass Spectrometry and Ion Processes, 1997
- A novel use of an ion-mobility mass spectrometer for the investigation of electron attachment to moleculesJournal of Physics B: Atomic, Molecular and Optical Physics, 1996
- A new experimental approach to investigate the kinetics of low energy electron attachment reactionsInternational Journal of Mass Spectrometry and Ion Processes, 1996
- Ion mobility spectrometry of halothane, enflurane, and isoflurane anesthetics in air and respired gasesAnalytical Chemistry, 1989
- Recent Advances in Ion Mobility Spectrometry for Explosives Vapor DetectionJournal of Testing and Evaluation, 1985