Rotating Electrode Potentiometry: Lowering the Detection Limits of Nonequilibrium Polyion-Sensitive Membrane Electrodes
Authors:
- 14 December 2000
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 73 (2) , 332-336
Abstract
A rotating electrode configuration is evaluated as a means to lower the detection limits of newly devised polyion-sensitive membrane electrodes (PSEs). Planar potentiometric polycation and polyanion PSEs are prepared by incorporating tridodecylmethylammonium chloride and calcium dinonylnaphthalenesulfonate, respectively, into plasticized PVC or polyurethane membranes and mounting disks of such films on an electrode body housed in a conventional rotating disk electrode apparatus. Rotation of the PSEs at 5000 rpm results in an enhancement in the detection limits toward heparin (polyanion) and protamine (polycation) of at least 1 order of magnitude (to 0.01 unit/mL for heparin; 0.02 μg/mL for protamine) over that observed when the EMF responses of the same electrodes are assessed using a stir-bar to achieve convective mass transport. A linear relationship between ω-1/2, where ω is the rotating angular frequency, and C1/2, the polyion concentration corresponding to half the total maximum ΔEMF response toward the polyion species, is observed. It is further shown that the rotating polycation sensor can be used as an end-point detector to greatly enhance (relative to nonrotated indicator electrode) the analytical resolution and precision for measurement of low concentrations of heparin when such samples are titrated with protamine. The theoretical basis for lowering the detection limits by rotating PSEs is discussed based on the unique nonequilibrium response mechanism of such sensors.Keywords
This publication has 6 references indexed in Scilit:
- Polyelectrolyte–surfactant complexes: an aqueous titration method to model ion-pairing within polymeric membranes of polyion-sensitive electrodesAnalytica Chimica Acta, 2000
- Renewable pH Cross-Sensitive Potentiometric Heparin Sensors with Incorporated Electrically Charged H+ IonophoresAnalytical Chemistry, 1999
- Determination of Low-Molecular-Weight Heparins and Their Binding to Protamine and a Protamine Analog Using Polyion-Sensitive Membrane ElectrodesAnalytical Biochemistry, 1999
- Polyion-sensitive membrane electrodes for detecting phosphate-rich biological polyanionsElectroanalysis, 1997
- Peer Reviewed: Polyion-Sensitive Membrane Electrodes for Biomedical AnalysisAnalytical Chemistry, 1996
- Trace analysis in solution using zeolite-modified electrodesAnalytical Chemistry, 1992