Abstract
Chemical Oxygen Demand (COD) estimates the amount of organic oxidizable matter in wastewaters. It is a critical parameter for assessing the quality of effluents prior to discharge, in the design and operation of wastewater treatment plants, and in environmental modelling and monitoring. In this study COD was determined by a closed reflux titrimetric method according to 5220C, APHA, 21st edn, 2005. This method is applicable to COD values between 40 and 400 mg L−1 and chloride concentrations up to 2000 mg L−1. Chloride interference is a serious problem in COD measurement for wastewaters containing low organic matter concentrations. The reliability of the results depends on a proper validation of the measurement procedure that includes the calculation and evaluation of the measurement uncertainty. This study develops a practical, understandable and simple way for calculating and assessing the Combined Standard Uncertainty (CSU) of COD measurement, mainly based on already existing quality control and validation data. The CSU assessment is based on the existing literature trueness and precision target limits, without any additional assumptions. Diagrams correlating the trueness of the COD measurement mean values with different chloride concentrations and the laboratory control charts' limits offer a tool for improving the performance of the determination and define the method application area. The validation data that were obtained in our laboratory (accredited according to ISO 17025) and the proposed methodology for CSU calculation were verified in the frame of intra and inter-laboratory measurements.Keywords
This publication has 12 references indexed in Scilit:
- Uncertainty in spectrophotometric analysis—“Error propagation break up”, a novel statistical method for uncertainty managementTalanta, 2011
- Optimization of the determination of chemical oxygen demand in wastewatersAnalytica Chimica Acta, 2011
- Uncertainty due to volumetric operations is often underestimatedTalanta, 2009
- Systematic errors in analytical measurement resultsJournal of Chromatography A, 2007
- Uncertainty of chemical oxygen demand determination in wastewater samplesAccreditation and Quality Assurance, 2003
- Harmonized guidelines for single-laboratory validation of methods of analysis (IUPAC Technical Report)Pure and Applied Chemistry, 2002
- Rapid Determination of Chemical Oxygen Demand (COD) Using Focused Microwave Digestion Followed by a Titrimetric MethodAnalytical Sciences, 2001
- Reduction of chloride ion interference in chemical oxygen demand (COD) determinations using bismuth-based adsorbentsAnalytica Chimica Acta, 1997
- Harmonized guidelines for internal quality control in analytical chemistry laboratories (Technical Report)Pure and Applied Chemistry, 1995
- Confidence interval approach for evaluating bias in laboratory methodsJournal of Analytical Methods in Chemistry, 1988