Rapid, Sensitive, and Specific Escherichia coli H Antigen Typing by Matrix-Assisted Laser Desorption Ionization–Time of Flight-Based Peptide Mass Fingerprinting
Authors:
Open Access
- 1 August 2015
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 53 (8) , 2480-2485
Abstract
Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) has gained popularity in recent years for rapid bacterial identification, mostly at the genus or species level. In this study, a rapid method to identify theEscherichia coliflagellar antigen (H antigen) at the subspecies level was developed using a MALDI-TOF MS platform with high specificity and sensitivity. Flagella were trapped on a filter membrane, and on-filter trypsin digestion was performed. The tryptic digests of each flagellin then were collected and analyzed by MALDI-TOF MS through peptide mass fingerprinting. Sixty-one reference strains containing all 53 H types and 85 clinical strains were tested and compared to serotyping designations. Whole-genome sequencing was used to resolve conflicting results between the two methods. It was found that DHB (2,5-dihydroxybenzoic acid) worked better than CHCA (α-cyano-4-hydroxycinnamic acid) as the matrix for MALDI-TOF MS, with higher confidence during protein identification. After method optimization, reference strains representing all 53E. coliH types were identified correctly by MALDI-TOF MS. A customE. coliflagellar/H antigen database was crucial for clearly identifying theE. coliH antigens. Of 85 clinical isolates tested by MALDI-TOF MS-H, 75 identified MS-H types (88.2%) matched results obtained from traditional serotyping. Among 10 isolates where the results of MALDI-TOF MS-H and serotyping did not agree, 60% of H types characterized by whole-genome sequencing agreed with those identified by MALDI-TOF MS-H, compared to only 20% by serotyping. This MALDI-TOF MS-H platform can be used for rapid and cost-effectiveE. coliH antigen identification, especially duringE. colioutbreaks.Keywords
This publication has 27 references indexed in Scilit:
- MS-H: A Novel Proteomic Approach to Isolate and Type the E. coli H Antigen Using Membrane Filtration and Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS)PLOS ONE, 2013
- Shiga Toxins and the Pathophysiology of Hemolytic Uremic Syndrome in Humans and AnimalsToxins, 2012
- Identification of the Shiga Toxin-Producing Escherichia coli O104:H4 Strain Responsible for a Food Poisoning Outbreak in Germany by PCRJournal of Clinical Microbiology, 2011
- Utility of Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry following Introduction for Routine Laboratory Bacterial IdentificationJournal of Clinical Microbiology, 2011
- Matrix-assisted laser-desorption/ionization BIOTYPER: experience in the routine of a University hospitalClinical Microbiology and Infection, 2011
- Performance of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Identification of Bacterial Strains Routinely Isolated in a Clinical Microbiology LaboratoryJournal of Clinical Microbiology, 2010
- Investigating the Quantitative Nature of MALDI-TOF MSMolecular & Cellular Proteomics, 2008
- Reproducibility in Protein Profiling by MALDI-TOF Mass SpectrometryClinical Chemistry, 2007
- Can the fliC PCR-Restriction Fragment Length Polymorphism Technique Replace Classic Serotyping Methods for Characterizing the H Antigen of Enterotoxigenic Escherichia coli Strains?Journal of Clinical Microbiology, 2006
- Subtyping of pathogenic Escherichia coli strains using flagellar (H)-antigens: serotyping versus fliC polymorphismsInternational Journal of Medical Microbiology, 2003