On the Importance of Image Gating for the Assay of Left Ventricular Mechanical Dyssynchrony Using SPECT
Authors:
- 9 November 2012
- journal article
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 53 (12) , 1892-1896
Abstract
The potential of SPECT for quantifying left ventricular mechanical dyssynchrony is increasingly appreciated. We sought to examine the incidence and impact of image gating errors on this quantification and to test a possible solution for affected studies. Methods: First, to establish whether and how gating error alone could affect the measurement of dyssynchrony, we performed a prospective study in which patients with pacemakers were studied twice: during normal rhythm without gating error and with gating error caused by pacemaker-induced dysrhythmia. Second, to understand the pattern and magnitude of gating error during our typical imaging practice, we retrospectively examined studies from a separate cohort of 64 patients who were referred for dyssynchrony evaluation. Third, to understand whether studies with gating error could be repaired for the purpose of quantifying dyssynchrony, we tested a correction algorithm on the pacemaker-induced dysrhythmia image set to see whether it repaired this set so as to approximate the patients’ normal rhythm image data. We subsequently applied this algorithm to the 64-patient cohort. Results: Pacemaker-induced gating error caused a spurious decrease in dyssynchrony magnitude. Among the 64-patient cohort, similar gating errors were common, and an inverse exponential relationship between gating-error magnitude and dyssynchrony magnitude was observed. The correction algorithm accurately repaired the pacemaker-induced dysrhythmia image set; when it was applied to the 64-patient cohort, the magnitude of the postcorrection increase in dyssynchrony magnitude was proportional to the magnitude of the gating error. Conclusion: Gating errors cause a spurious reduction in SPECT assay of dyssynchrony magnitude. In our standard imaging practice, gating errors were common. Post hoc correction appears to be feasible.Keywords
This publication has 14 references indexed in Scilit:
- Ventricular dyssynchrony assessed by gated myocardial perfusion SPECT using a geometrical approach: a feasibility studyEuropean Journal of Nuclear Medicine and Molecular Imaging, 2011
- A Prospective Pilot Study to Evaluate the Relationship Between Acute Change in Left Ventricular Synchrony After Cardiac Resynchronization Therapy and Patient Outcome Using a Single-Injection Gated SPECT ProtocolCirculation: Cardiovascular Imaging, 2011
- Optimal left ventricular lead position assessed with phase analysis on gated myocardial perfusion SPECTEuropean Journal of Nuclear Medicine and Molecular Imaging, 2010
- Evaluation of mechanical dyssynchrony and myocardial perfusion using phase analysis of gated SPECT imaging in patients with left ventricular dysfunctionJournal of Nuclear Cardiology, 2008
- Repeatability and reproducibility of phase analysis of gated single-photon emission computed tomography myocardial perfusion imaging used to quantify cardiac dyssynchronyNuclear Medicine Communications, 2008
- Can LV Dyssynchrony as Assessed with Phase Analysis on Gated Myocardial Perfusion SPECT Predict Response to CRT?Journal of Nuclear Medicine, 2007
- Evaluation of left ventricular mechanical dyssynchrony as determined by phase analysis of ECG-gated SPECT myocardial perfusion imaging in patients with left ventricular dysfunction and conduction disturbancesJournal of Nuclear Cardiology, 2007
- Phase Analysis of Gated Myocardial Perfusion Single-Photon Emission Computed Tomography Compared With Tissue Doppler Imaging for the Assessment of Left Ventricular DyssynchronyJACC, 2007
- Onset of left ventricular mechanical contraction as determined by phase analysis of ECG-gated myocardial perfusion SPECT imaging: Development of a diagnostic tool for assessment of cardiac mechanical dyssynchronyJournal of Nuclear Cardiology, 2005
- Effects of myocardial wall thickness on SPECT quantificationIEEE Transactions on Medical Imaging, 1990