Determination of REEs in natural water by ICP-MS with the aid of an automatic column changing system
- 7 May 2010
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 25 (8) , 1253-1258
Abstract
An automatic column changing system was developed for preconcentration and measurement of rare earth elements (REEs) in natural water samples, where syringe driven chelating columns (SDCCs) were applied to the hybrid (off-line operation and on-line operation) solid phase extraction of REEs. The sample loading was carried out off-line prior to the measurement. After that, the SDCCs were set into the column holder of the automatic column changing system and REEs were on-line eluted and measured by an inductively coupled plasma mass spectrometer (ICP-MS). The present automatic column changing system permitted continuously automatic measurement of 30 samples, while 3 min was enough for measuring one sample. The reproducibilities of REEs' signals obtained with two kinds of SDCCs showed that both of them are fit for the hybrid solid phase extraction method for preconcentration of REEs. The analytical detection limits (ADL) of REEs were in the range from 0.013 pg mL−1 for Tm to 0.15 pg mL−1 for Ce when 10 mL of water sample was loaded to each SDCC. The usefulness of the present method was confirmed by analysing NMIJ CRM 7201-a. After that, REEs in Lake Baikal water samples from depth of 50, 100, 150, 200, 250 m were determined. The results showed that dissolved REEs in the sample of 50 m depth were significantly lower than other samples, while the total REEs in the sample of each depth were close to one another. The distribution of REEs in Lake Baikal water samples was also discussed using shale normalized REEs distribution pattern.Keywords
This publication has 16 references indexed in Scilit:
- On-line elution of iron hydroxide coprecipitate carrier for determination of REEs in natural water by mix-gas ICP-MSJournal of Analytical Atomic Spectrometry, 2009
- Multielement Determination of Trace Metals in Seawater by Inductively Coupled Plasma Mass Spectrometry after Tandem Preconcentration Using a Chelating ResinBulletin of the Chemical Society of Japan, 2005
- Strontium isotopes and rare earth elements as tracers of groundwater–lake water interactions, Lake Naivasha, KenyaApplied Geochemistry, 2003
- Determination of transition and rare earth elements in seawater by flow injection inductively coupled plasma time-of-flight mass spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 2001
- Multielement Determination of Trace Elements in Coastal Seawater by Inductively Coupled Plasma Mass Spectrometry with Aid of Chelating Resin PreconcentrationBulletin of the Chemical Society of Japan, 1999
- Determination of trace elements in seawater by fluorinated metal alkoxide glass-immobilized 8-hydroxyquinoline concentration and high-resolution inductively coupled plasma mass spectrometry detectionAnalytica Chimica Acta, 1998
- Multielement Determination of Rare Earth Elements in Coastal Seawater by Inductively Coupled Plasma Mass Spectrometry after Preconcentration Using Chelating ResinBulletin of the Chemical Society of Japan, 1995
- Simultaneous multi-element analysis for trace metals in sea water by inductively-coupled plasma/atomic emission spectrometry after batch preconcentration on a chelating resinAnalytica Chimica Acta, 1987
- Rare-earth distributions with a positive Ce anomaly in the Western North Atlantic OceanNature, 1983
- The rare earth elements in seawaterNature, 1982