Abstract
Custom cutting guides based on pre-operative imaging have been introduced for total knee arthroplasty (TKA). The aim of this prospective cohort study was to assess the reliability of repeated placement of custom cutting guides by multiple surgeons in a group of patients undergoing TKA. Custom cutting guides (ShapeMatch®, Stryker Orthopaedics) were designed from pre-operative MRI scans. The treating surgeon placed each guide on the femur and tibia of each patient three times without pinning the block. The three-dimensional position and orientation of the guide was measured for each repetition using a computer navigation system. The surgeon was blinded to the navigation system display. Data from 24 patients and 6 surgeons were analyzed. Intraclass correlation coefficients for all measurement parameters were in the range 0.889–0.997 (excellent), and all comparisons were statistically significant (p < 0.001). The range for femoral varus/valgus was 0.0–1.5°, with 96% of patients being within 0.5°. For femoral flexion/extension the range was 0.0–3.5° (92% within 2.5°). On the tibia, varus/valgus had a range of 0.0–1.0° (92% within 0.5°), and for slope the range was 0.0–3.5° (92% within 2.5°). The high degree of agreement indicated that intra-surgeon variation was minimal and that the technique is reliable.Keywords
This publication has 14 references indexed in Scilit:
- Patient-Specific Instrumentation for Total Knee ArthroplastyOrthopedic Clinics of North America, 2012
- Reliability of frames of reference used for tibial component rotation in total knee arthroplastyComputer Aided Surgery, 2011
- The Use of Disposable Cutting Blocks and Trials For Primary Total Knee ArthroplastyTechniques in Knee Surgery, 2010
- Internal rotational error of the tibial component is a major cause of pain after total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2010
- Rotational alignment of the tibial component in total knee arthroplasty is better at the medial third of tibial tuberosity than at the medial borderBMC Musculoskeletal Disorders, 2010
- Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignmentInternational Orthopaedics, 2008
- Computer-assisted and conventional total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2008
- Interobserver and Intra-observer Errors in Obtaining Visually Selected Anatomical Landmarks During Registration Process in Non–Image-Based Navigation-Assisted Total Knee ArthroplastyThe Journal of Arthroplasty, 2007
- Alignments and Clinical Results in Conventional and Navigated Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2007
- How Accurate is Current TKR Instrumentation?Clinical Orthopaedics and Related Research, 2003