Incidence, Anatomical Location, and Clinical Significance of Compressions and Fractures in Infrapopliteal Balloon-Expandable Metal Stents
Authors:
- Dimitris KarnabatidisDKDimitris Karnabatidis
- Konstantinos KatsanosKKKonstantinos Katsanos
- Stavros SpiliopoulosStavros Spiliopoulos
- Athanasios DiamantopoulosADAthanasios Diamantopoulos
- George C. KagadisGKGeorge C. Kagadis
- Dimitris SiablisDSDimitris Siablis
- 1 February 2009
- journal article
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 16 (1) , 15-22
Abstract
To investigate the incidence, anatomical location, and clinical impact of fractures and/or compression of infrapopliteal balloon-expandable metal stents implanted for critical limb ischemia (CLI) treatment. This prospective study included 63 CLI patients (45 men; mean age 71.3+/-9.5 years) who had been treated with infrapopliteal angioplasty and stent placement for 191 lesions in 84 limbs. In all, 369 stents (296 stainless steel and 73 cobalt-chromium alloy) were implanted; 239 were placed overlapping in tandem lesions. Mean length of the overall stented segment was 4.4+/-6.3 cm (range 1.6-14.0). Stents were located in the tibioperoneal (n = 34), anterior tibial (n = 195), posterior tibial (n = 63), and peroneal (n = 77) arteries. Follow-up consisted of digital subtraction angiography and infrapopliteal radiography imaging at 2 different angles. Evaluation of stents for the presence of fracture and/or compression was done after digital processing at the highest possible magnification. Stent fractures were defined according to published standards, whereas compression was classified as severe shape alteration and/or collapse of the stent mesh. Angiographic restenosis was based on a 50% threshold. Mean follow-up was 15+/-11 months (range 6-60). Image analysis detected 1 (0.3%) severe stent fracture (complete separation and misalignment of stent struts) and 11 (3.0%) stent compressions. Infrapopliteal stent fracture and compressions were associated with increased artery restenosis [100% (12/12) versus 47.3% (169/357), p<0.001] and an increased rate of clinical deterioration and clinically-driven reinterventions [41.7% (5/12 limbs) versus 19.4% (14/72 limbs), p = 0.04]. The single fracture and most of the compressions were located in the distal third of the anterior tibial artery. Stent fractures and compressions of infrapopliteal balloon-expandable metal stents are infrequent. However, they may be related to increased restenosis.Keywords
This publication has 21 references indexed in Scilit:
- Superior Mesenteric Artery Stent Fracture Producing Stenosis and Recurrent Chronic Mesenteric Ischemia: Case ReportVascular and Endovascular Surgery, 2008
- Infrapopliteal Application of Paclitaxel-eluting Stents for Critical Limb Ischemia: Midterm Angiographic and Clinical ResultsJournal of Vascular and Interventional Radiology, 2007
- Rare and Fatal Complication of Gianturco Tracheobronchial StentThe Annals of Thoracic Surgery, 2007
- Sirolimus-eluting Versus Bare Stents After Suboptimal Infrapopliteal Angioplasty for Critical Limb Ischemia: Enduring 1-year Angiographic and Clinical BenefitJournal of Endovascular Therapy, 2007
- Fracture of a carotid stent: An unexpected complicationJournal of Vascular Surgery, 2007
- Incidence and clinical impact of coronary stent fracture after sirolimus‐eluting stent implantationCatheterization and Cardiovascular Interventions, 2006
- Long-Segment SFA Stenting—The Dark Sides: In-Stent Restenosis, Clinical Deterioration, and Stent FracturesJournal of Endovascular Therapy, 2005
- PTA Versus Carbofilm-Coated Stents in Infrapopliteal Arteries: Pilot StudyCardioVascular and Interventional Radiology, 2005
- Fracture of a Renal Artery Stent Due to Mobile KidneyCardioVascular and Interventional Radiology, 2005
- Stent fracture and restenosis in the drug‐eluting stent eraCatheterization and Cardiovascular Interventions, 2003