Velocity Criteria for Intracranial Stenosis Revisited
Authors:
- 1 December 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Stroke
- Vol. 42 (12) , 3429-3434
Abstract
Background and Purpose—: Intracranial atherosclerotic disease is associated with a high risk of stroke recurrence. We aimed to determine accuracy of transcranial Doppler screening at laboratories that share the same standardized scanning protocol. Methods—: Patients with symptoms of cerebral ischemia were prospectively studied. Stroke Outcomes and Neuroimaging of Intracranial Atherosclerosis (SONIA) criteria were used for identification of ≥50% stenosis. We determined velocity cutoffs for ≥70% stenosis on digital subtraction angiography by Warfarin–Aspirin Symptomatic Intracranial Disease criteria and evaluated novel stenotic/prestenotic ratio and low-velocity criteria. Results—: A total of 102 patients with intracranial atherosclerotic disease (age 57±13 years; 72% men; median National Institutes of Health Stroke Scale 3, interquartile range 6) provided 690 transcranial Doppler/digital subtraction angiography vessel pairs. On digital subtraction angiography, ≥50% stenosis was found in 97 and ≥70% stenosis in 62 arteries. Predictive values for transcranial Doppler SONIA criteria were similar ( P >0.9) between middle cerebral artery (sensitivity 78%, specificity 93%, positive predictive value 73%, negative predictive value 94%, and overall accuracy 90%) and vertebral artery/basilar artery (69%, 98%, 88%, 93%, and 92%). As a single velocity criterion, most sensitive mean flow velocity thresholds for ≥70% stenosis were: middle cerebral artery >120 cm/s (71%) and vertebral artery/basilar artery >110 cm/s (55%). Optimal combined criteria for ≥70% stenosis were: middle cerebral artery >120 cm/s, or stenotic/prestenotic ratio ≥3, or low velocity (sensitivity 91%, specificity 80%, receiver operating characteristic 0.858), and vertebral artery/basilar artery >110 cm/s or stenotic/prestenotic ratio ≥3 (60%, 95%, 0.769, respectively). Conclusions—: At laboratories with a standardized scanning protocol, SONIA mean flow velocity criteria remain reliably predictive of ≥50% stenosis. Novel velocity/ratio criteria for ≥70% stenosis increased sensitivity and showed good agreement with invasive angiography.Keywords
This publication has 25 references indexed in Scilit:
- Applications and Advantages of Power Motion-Mode Doppler in Acute Posterior Circulation Cerebral IschemiaStroke, 2008
- Noninvasive Detection of Diffuse Intracranial DiseaseStroke, 2007
- The Stroke Outcomes and Neuroimaging of Intracranial Atherosclerosis (SONIA) TrialNeurology, 2007
- Validation of Transcranial Doppler With Computed Tomography Angiography in Acute Cerebral IschemiaStroke, 2007
- The Accuracy of Transcranial Doppler in the Diagnosis of Middle Cerebral Artery StenosisCerebrovascular Diseases, 2007
- The Spencer's Curve: Clinical Implications of a Classic Hemodynamic ModelJournal of Neuroimaging, 2007
- Ischemic Stroke Subtype Incidence Among Whites, Blacks, and HispanicsCirculation, 2005
- Stroke Outcomes and Neuroimaging of Intracranial Atherosclerosis (SONIA): Design of a Prospective, Multicenter Trial of Diagnostic TestsNeuroepidemiology, 2004
- Noninvasive detection of occlusive disease of the carotid siphon and middle cerebral arteryAnnals of Neurology, 1990
- Transcranial Doppler ultrasound for the assessment of intracranial arterial flow velocity—Part 2. Evaluation of intracranial arterial diseaseSurgical Neurology, 1987