Wearable 3-Lead Electrocardiogram Placement Model for Fleet Sizing of Medical Devices
Authors:
- Katya ArquillaKAKatya Arquilla
- Sarah LearySLSarah Leary
- Andrea K. WebbAWAndrea K. Webb
- Allie P. AndersonAAAllie P. Anderson
- 1 November 2020
- journal article
- research article
- Published by Aerospace Medical Association in Aerospace Medicine and Human Performance
- Vol. 91 (11) , 868-875
Abstract
BACKGROUND: Electrocardiography (ECG) provides valuable information on astronaut physiological and psychological health. ECG monitoring has been conducted during crewed missions since the beginning of human spaceflight and will continue during astronauts upcoming long-duration exploration missions (LDEMs) in support of automated health monitoring systems. ECG monitoring is traditionally performed in clinical environments with single-use, adhesive electrodes in a 3, 6, or 12-lead configuration placed by a trained clinician. In the space exploration environment, astronauts self-place electrodes without professional assistance. Wearable ECG systems are an attractive option for automated health monitoring, but electrode placement has not been quantified to a high enough degree to avoid artifacts within the data due to position changes. This variability presents challenges for physician-limited, autonomous health monitoring, so quantifying electrode placement is key in the development of reliable, wearable ECG monitoring systems.METHODS: We present a method of quantifying electrode placement for 3-lead, chest-mounted ECG using easy-to-measure, two-dimensional chest measurements.RESULTS: We find that male and female dimensions require different electrode positioning computations, but there is overlap in positioning between men and women. The distribution of electrodes vertical positions is wider than their horizontal positions.DISCUSSION: These results can be translated directly to ECG wearable design for the individual and for the size range and adjustability required for the astronaut fleet. Implementation of this method will improve the reliability in placement and fit of future wearables, increasing comfort and usability of these systems and subsequently augmenting autonomous health monitoring capabilities for exploration medicine.Arquilla K, Leary S, Webb AK, Anderson AP. Wearable 3-lead electrocardiogram placement model for fleet sizing of medical devices. Aerosp Med Hum Perform. 2020; 91(11):868875.Keywords
This publication has 10 references indexed in Scilit:
- Textile Electrocardiogram (ECG) Electrodes for Wearable Health MonitoringSensors, 2020
- Advanced biosensors for monitoring astronauts’ health during long-duration space missionsBiosensors and Bioelectronics, 2018
- An analysis of the variability of anatomical body references within ready-to-wear garment sizes2016
- Effects of Ready-to-Wear Sizing Conventions on Sensor Placement for Medical Wearable Sensing1Journal of Medical Devices, 2016
- Child body shape measurement using depth cameras and a statistical body shape modelErgonomics, 2014
- Wearable Textile Electrodes for ECG MeasurementAdvances in Electrical and Electronic Engineering, 2013
- Accuracy in ECG lead placement among technicians, nurses, general physicians and cardiologistsInternational Journal Of Clinical Practice, 2007
- Accuracy of ECG electrode placement by emergency department cliniciansEmergency Medicine Australasia, 2007
- A standardized procedure for locating and documenting ecg chest electrode positions: Consideration of the effect of breast tissue on ecg amplitudes in womenJournal of Electrocardiology, 1998
- Skin-Electrode Impedance and Its Effect on Recording Cardiac PotentialsCirculation, 1966