Direct hydrogenation of liquid organic hydrogen carriers (LOHCs) from mixed H2/CO2 streams could integrate hydrogen separation and storage within a single process. However, the effects of LOHC molecular structure on hydrogenation performance and competing CO2 methanation remain insufficiently understood. Here, toluene (TOL) and benzyltoluene (H0-BT), representative single- and double-ring LOHCs, were compared over Ru/TiO2/Al2O3 under continuous-flow conditions. TOL achieved nearly complete hydrogenation at 100 °C within a low-temperature window, where CH4 formation was limited. In contrast, H0-BT required temperatures above 160 °C and reached a maximum degree of hydrogenation (DoH) of approximately 52% at 260 °C, with H6-BT as the predominant hydrogenated product. Quantified CH4 formation rates followed the order H2/CO2 blank > TOL hydrogenation > H0-BT hydrogenation, indicating that methanation accessibility depends on the LOHC-derived surface state. In situ diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) revealed rapid depletion of TOL-derived aromatic species, whereas H0-BT-derived species persisted under inert and hydrogenation conditions. This slower surface renewal was consistent with H6-BT accumulation, incomplete hydrogenation to H12-BT, and restricted access of CO2 to methanation-active Ru sites. Under 75% H2/25% CO2 at 100 °C and 40 bar, TOL maintained approximately 100% DoH for 55 h without a measurable decline in activity. Comparative techno-economic analysis (TEA) indicated that the integrated route could reduce hydrogen separation and storage costs relative to conventional pressure swing adsorption followed by hydrogenation, primarily by avoiding the separate purification unit. These findings provide mechanistic and process-level criteria for selecting LOHCs for direct hydrogen storage from CO2-containing streams.