Whole-Surface Analysis of Semiconductor Wafers by Accumulating Short-Time Mapping Data of Total-Reflection X-ray Fluorescence Spectrometry
Authors:
- 26 January 2002
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 74 (5) , 1104-1110
Abstract
Total-reflection X-ray fluorescence (TXRF) spectrometry with no chemical preconcentration, often called “straight-TXRF”, is now widely used in the semiconductor industry. The small detection area of TXRF enables mapping measurement of contamination of the semiconductor surface, which is very useful in process characterization. However, the small detection area had been believed to limit rapid whole-surface analysis. Contrary to this general understanding, in this study we demonstrated that a new method, called “sweeping-TXRF”, which is essentially short-time multipoint mapping by straight-TXRF, can rapidly provide an average concentration. A considerable problem of this method is the contribution of errors in glancing angle and areal element distribution to the fluorescence. Using statistics, we examined the errors and demonstrated that most of them are canceled and are not significant in actual semiconductor applications. The results of an experiment that measured localized 6 × 1010 atoms cm-2 nickel contamination supported the above conclusion. Applying sweeping-TXRF to existing TXRF instruments is easythe only requirement is a small software modification. We believe that sweeping-TXRF will be utilized for rapid whole-surface analysis in many fields, especially in the semiconductor industry.Keywords
This publication has 10 references indexed in Scilit:
- Multi-batch Preparation of Standard Samples from a Single Doped Solution for Cross-checking in Surface Metal Analyses of Silicon Wafers.Analytical Sciences, 2000
- Error factors in quantitative total reflection x-ray fluorescence analysisX-Ray Spectrometry, 1999
- Enhanced analysis of particles and vapor phase decomposition droplets by total-reflection X-ray fluorescenceSpectrochimica Acta Part B: Atomic Spectroscopy, 1999
- Novel methods of TXRF analysis for silicon wafer surface inspectionAnalytical and Bioanalytical Chemistry, 1999
- Accuracy of Total Reflection X-Ray Fluorescence Spectrometry near the Detection LimitAnalytical Sciences, 1998
- Improvement of Total Reflection X-ray Fluorescence (TXRF) spectrochemical analysis for silicon wafersSpectrochimica Acta Part B: Atomic Spectroscopy, 1997
- Standard Sample Preparation for the Analysis of Several Metals on Silicon WaferAnalytical Sciences, 1996
- A Standard Sample Preparation Method for the Determination of Metal Impurities on a Silicon Wafer by Total Reflection X-Ray Fluorescence SpectrometrytAnalytical Sciences, 1995
- Analysis of trace metals on silicon surfacesAnalytical and Bioanalytical Chemistry, 1992
- X-ray induced fluorescence spectrometry at grazing incidence for quantitative surface and layer analysisAnalytical and Bioanalytical Chemistry, 1991