An assessment of clinically optimal gold marker length and diameter for pelvic radiotherapy verification using an amorphous silicon flat panel electronic portal imaging device
Authors:
- J StratfordJSJ Stratford
- J DaviesJDJ Davies
- C McCarthyCMC McCarthy
- R SwindellRSR Swindell
- J SykesJSJ Sykes
- C J MooreCMC J Moore
- P PricePPP Price
- V S KhooVKV S Khoo
- 1 August 2005
- journal article
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 78 (932) , 737-741
Abstract
Verification of target organ position is essential for the accurate delivery of conformal radiotherapy. Megavoltage electronic portal imaging with flat panel amorphous silicon detectors delivers high quality images that can be used for verification of bony landmark position. Gold markers implanted into the target organ can be visualized and used as a surrogate of actual organ position. On-line compensation for marker displacement, by adjusting patient position, can reduce geometric errors associated with radiation delivery. This study assesses the optimal marker length and diameter to be used with an amorphous silicon (a-Si) flat panel detector and electronic portal images (EPIs), prior to implementation of a clinical programme of gold marker insertion in prostate cancer patients. Seven marker sizes varying from 3 mm to 8 mm in length and 0.8 mm to 1.1 mm in diameter were investigated in a group of patients undergoing pelvic radiotherapy using an 8 MV Elekta SL20 linear accelerator. Markers were placed on the skin entry and exit sites of the treatment beam and EPIs in both lateral and anterior pelvic views were acquired. Three observers independently assessed visibility success and failure using a subjective scoring system. Markers less than 5 mm in length or 0.9 mm in diameter were poorly visualized (<70% visualization success in lateral EPIs). The marker measuring 0.9 mm × 5 mm appears to be clinically optimal in pelvic radiotherapy patients (80% visualization success in lateral EPIs) and will be used for actual organ implantation.Keywords
This publication has 17 references indexed in Scilit:
- Technical aspects of daily online positioning of the prostate for three-dimensional conformal radiotherapy using an electronic portal imaging deviceInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2003
- (Non)-migration of radiopaque markers used for on-line localization of the prostate with an electronic portal imaging deviceInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2003
- Organ motion and its managementInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2001
- Feasibility of automatic marker detection with an a-Si flat-panel imagerPhysics in Medicine & Biology, 2001
- Preliminary Results of a Randomized Radiotherapy Dose-Escalation Study Comparing 70 Gy With 78 Gy for Prostate CancerJournal of Clinical Oncology, 2000
- Comparison of radiation side-effects of conformal and conventional radiotherapy in prostate cancer: a randomised trialThe Lancet, 1999
- Dose escalation with three-dimensional conformal radiation therapy affects the outcome in prostate cancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1998
- Automated localization of the prostate at the time of treatment using implanted radiopaque markers: Technical feasibilityInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1995
- Prostate motion during standard radiotherapy as assessed by fiducial markersRadiotherapy and Oncology, 1995
- Neoadjuvant hormonal therapy improves the therapeutic ratio in patients with bulky prostatic cancer treated with three-dimensional conformal radiation therapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1994