Ultrasensitive measurement of gas refractive index based on cascaded Mach–Zehnder interferometers and Vernier effect
Authors:
- 2 June 2021
- journal article
- research article
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (9) , 095108
Abstract
An ultrasensitive gas refractive index (RI) sensor based on fiber Mach–Zehnder interferometers (MZIs) and Vernier effect is proposed and demonstrated. The sensor consists of two cascaded fiber MZIs, one of which serves as a reference unit and is fabricated by fusion splicing a section of symmetrical side-hole fiber in between two short pieces of multi-mode fiber (MMF); the other acts as a sensing unit, which is composed of a section of tapered single-mode fiber sandwiched between two sections of MMF. The two MZIs are designed to have similar free spectral range for generating optical Vernier effect. Because the two MZIs have different responses to external RI, the RI-related Vernier effect can be obtained and the RI sensitivity can be improved, while there is no temperature sensitivity enhancement because the two MZIs have the same response to temperature. Thus the structure has low temperature crosstalk when obtaining high RI sensitivity. Experimental results show that the gas RI sensor has an ultrahigh sensitivity of 4.2 × 10 4 nm RIU −1 (RI unit). At the same time, the temperature cross-sensitivity is only 2.2 × 10 −6 RIU °C −1 . Therefore, the proposed sensor has potential applications for modern gas concentration monitoring in a large dynamic range.Keywords
Funding Information
- National Defense Pre-Research Foundation of China (6140414030102)
- Fundamental Research Funds for the Central Universities (205201023)
This publication has 18 references indexed in Scilit:
- Hollow-Core Photonic Crystal Fiber Mach–Zehnder Interferometer for Gas SensingSensors, 2020
- High-accuracy hybrid fiber-optic Fabry-Pérot sensor based on MEMS for simultaneous gas refractive-index and temperature sensingOptics Express, 2019
- Temperature-compensated fiber-optic Fabry–Perot interferometric gas refractive-index sensor based on hollow silica tube for high-temperature applicationSensors and Actuators B: Chemical, 2017
- Fringe visibility enhanced Fabry-Perot interferometer and its application as gas refractometerSensors and Actuators B: Chemical, 2016
- In-fiber Mach-Zehnder interferometer for gas refractive index measurements based on a hollow-core photonic crystal fiberOptics Express, 2016
- Ultra-high sensitivity Fabry–Perot interferometer gas refractive index fiber sensor based on photonic crystal fiber and Vernier effectOptics Letters, 2015
- Sensitivity enhancing of transition mode long-period fiber grating as methane sensor using high refractive index polycarbonate/cryptophane A overlay depositionSensors and Actuators B: Chemical, 2015
- High sensitivity gas refractometer based on all-fiber open-cavity Fabry–Perot interferometer formed by large lateral offset splicingJournal of the Optical Society of America B, 2012
- In-fiber Mach–Zehnder interferometer formed by large lateral offset fusion splicing for gases refractive index measurement with high sensitivitySensors and Actuators B: Chemical, 2011
- Sensing applications of a low-coherence fibre-optic interferometer measuring the refractive index of airSensors and Actuators B: Chemical, 2001