Four-dimensional fetal echocardiography with spatiotemporal image correlation (STIC): A systematic study of standard cardiac views assessed by different observers
Open Access
- 1 May 2005
- journal article
- research article
- Published by Taylor & Francis in The Journal of Maternal-Fetal & Neonatal Medicine
- Vol. 17 (5) , 323-331
Abstract
Objective. To test the agreement between observers and reproducibility of a technique to display standard cardiac views of the left and right ventricular outflow tracts from four-dimensional volume datasets acquired with Spatiotemporal Image Correlation (STIC). Methods. A technique was developed to obtain dynamic multiplanar images of the left ventricular outflow tract (LVOT) and right ventricular outflow tract (RVOT) from volume datasets acquired with STIC. Volume datasets were acquired from fetuses with normal cardiac anatomy. Twenty volume datasets of satisfactory quality were pre-selected by one investigator. The data was randomly assigned for a blinded review by two independent observers with previous experience in fetal echocardiography. Only one volume dataset was used for each fetus. After a training session, the observers obtained standardized cardiac views of the LVOT and RVOT, which were scored on a scale of 1 to 5, based on diagnostic value and image quality (1 = unacceptable, 2 = marginal, 3 = acceptable, 4 = good, and 5 = excellent). Median scores and interquartile range, as well as inter- and intraobserver agreement were calculated for each view. Results. The mean menstrual age at the time of volume acquisition was 25.5 ± 4.5 weeks. Median scores (interquartile range) for LVOT images, obtained by the first and second observers, were 3.5 (2.25–5.00) and 4 (3.00–5.00), respectively. The median scores (interquartile range) for RVOT images obtained by the first and second observers were 3 (3.00–5.00) and 3 (2.00–4.00), respectively. The interobserver intraclass correlation coefficient for the LVOT was 0.693 (95% CI 0.380–0.822), and 0.696 (95% CI 0.382–0.866) for the RVOT. For the intraobserver agreement analysis, observer 1 gave higher scores to the LVOT the second time the volumes were analyzed [LVOT: 3.50 (2.25–5.00) vs. 5.00 (4.00–5.00, p = 0.008)]. Conclusion. STIC can be reproducibly used to evaluate fetal cardiac outflow tracts by independent examiners. Slightly better image quality rating scores during the intraobserver variability trial suggests the presence of a learning curve for the manipulation and analysis of volume data obtained by STIC.Keywords
This publication has 49 references indexed in Scilit:
- Factors influencing the prenatal detection of structural congenital heart diseasesUltrasound in Obstetrics & Gynecology, 2002
- Accuracy of Prenatal Diagnosis of Congenital Heart DefectsFetal Diagnosis and Therapy, 2001
- Comparative analysis of pattern, management and outcome of pre‐ versus postnatally diagnosed major congenital heart disease: a population‐based studyUltrasound in Obstetrics & Gynecology, 2001
- 3D Real-Time Imaging of the Fetal HeartFetal Diagnosis and Therapy, 2000
- Efficacy of routine fetal ultrasound screening for congenital heart disease in Isère county, FrancePrenatal Diagnosis, 1999
- Evaluation of prenatal diagnosis of congenital heart diseasePrenatal Diagnosis, 1998
- Sonographic screening to detect fetal cardiac anomalies: A 5-year experience with 111 abnormal casesObstetrics & Gynecology, 1997
- Fetal echocardiography in three and four dimensionsUltrasound in Medicine & Biology, 1996
- The accuracy of antenatal fetal echocardiography screening in high- and low-risk patientsAmerican Journal of Obstetrics and Gynecology, 1995
- Evaluation of prenatal diagnosis of congenital heart diseasePrenatal Diagnosis, 1993