Optic Nerve Sheath Diameter Correlation with Elevated Intracranial Pressure Determined via Ultrasound
Open Access
- 27 February 2019
- journal article
- research article
- Published by Springer Nature in Cureus
- Vol. 11 (2) , e4145
Abstract
The early detection of elevated intracranial pressure (ICP) can not only prevent mortality but also aid in more aggressive management. Brain computed tomography (CT) is a mainstay modality in detecting elevated ICP, but the feasibility of using brain CTs to detect elevated ICP in critically ill patients is limited, especially for patients who require high levels of inotropic support. The optic nerve sheath is a direct extension of the brain meninges. Therefore, the elevation of ICP is directly transmitted to the sheath. Measuring the optic nerve sheath diameter (ONSD) through ultrasound (US) is a bedside, noninvasive means to detect elevated ICP. The goal of this study was to assess the correlation of ONSD with elevated ICP as measured via US in an intensive care unit (ICU). We conducted a six-month prospective, single-center, observational study of mass effect stroke patients aged 18 to 65 years who had a traumatic brain injury (TBI) and were admitted to the ICU. Patients with chronic hydrocephalus, extensive local orbit trauma, a pre-existing ocular disease affecting the optic nerve and/or orbital cavity, hyperthyroidism with exophthalmos, and facial trauma affecting the orbits and/or eyeballs were excluded. We measured the ONSD at the entry of optic nerve into the globe using two-dimensional (2D) US. One hundred patients were included in the study. Forty-nine patients had diffuse cerebral edema detected on CT scan correlating with increased ONSD notable via bedside US. The mean ONSD related to CT-detectable elevated ICP was 0.61 cm. The sensitivity for the ONSD cut-off value of ≥5.8 mm was 94% (95% confidence interval [CI], 84.05% to 98.79%), and the specificity was 96.08% (95% CI, 86.7% to 99.52%).The positive predictive value was 92.08% (95% CI, 86.28% to 98.96%), and the negative predictive value was 94.23% (95% CI, 84.47% to 98.00%). The greatest accuracy in ONSD was found with a cut-off of >0.58 cm in patients with positive CT brain findings. Therefore, US can be used as an initial screening test when physicians suspect a patient has elevated ICP.Keywords
This publication has 15 references indexed in Scilit:
- Sonography of the Optic Nerve Sheath Diameter for Detection of Raised Intracranial Pressure Compared to Computed TomographyJournal of Ultrasound in Medicine, 2015
- Accuracy of Optic Nerve Sheath Diameter Measurement by Emergency Physicians Using Bedside UltrasoundThe Journal of Emergency Medicine, 2015
- Correlation of optic nerve sheath diameter measurements by computed tomography and magnetic resonance imagingThe American Journal of Emergency Medicine, 2013
- Intracranial Pressure Monitoring: Invasive versus Non-Invasive Methods—A ReviewCritical Care Research and Practice, 2012
- Ultrasound measurement of optic nerve sheath diameter in patients with a clinical suspicion of raised intracranial pressureEmergency Medicine Journal, 2010
- Risk factors and complications of intracranial pressure monitoring with a fiberoptic deviceJournal of Clinical Neuroscience, 2009
- The role of optic nerve ultrasonography in the diagnosis of elevated intracranial pressureEmergency Medicine Journal, 2007
- Transorbital Sonographic Monitoring of Optic Nerve Diameter in Patients With Severe Brain InjuryTransplantation Proceedings, 2006
- Sonographic Evaluation of Optic Nerve Diameter in Children With Raised Intracranial PressureJournal of Ultrasound in Medicine, 2005
- Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: ultrasound findings during intrathecal infusion testsJournal of Neurosurgery, 1997