Ranking PVC Roofing Membranes Using Thermal Analysis
Authors:
- 1 February 1993
- journal article
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 5 (1) , 83-95
Abstract
The effects of accelerated heat aging on three polyvinyl chloride (PVC) roofing membranes was determined using thermogravimetry (TG), dynamic mechanical thermal analysis (DMA), and tensile testing. The heat aging was done at 100°C and 130°C. In general, it was found that the degradation of the reinforced PVC roofing membranes was proportional to the aging temperature and exposure time. Furthermore, it was found that these thermoanalytical techniques can be used to not only record the changes incurred by the samples due to heat aging, but also to provide a ranking of the heat stability of the various materials. The order of stability, using these techniques, was determined to be V1<V3<V2, which corresponded with the observed order of stability from actual records obtained on roofs. The results obtained demonstrate that TG and DMA, in conjunction with tensile testing, provide a viable, routine method of evaluating the quality of single‐ply PVC‐based roofing membranes.Keywords
This publication has 5 references indexed in Scilit:
- Characterization of ethylene-propylene-diene monomer (EPDM) roofing membranes using thermogravimetry and dynamic mechanical analysisThermochimica Acta, 1991
- PVC Technology1984
- The formation of volatile pyrolyzates form poly(vinyl chloride)Journal of Applied Polymer Science, 1980
- On the thermal degradation of poly(vinyl chloride). III. Structural changes during degradation in nitrogenJournal of Applied Polymer Science, 1975
- Thermal decomposition of poly(vinyl chloride)Journal of Polymer Science, 1959