Central Composite Design for Solvent Extraction of Oil from Neem (Azadirachta indica) seed

Authors:

Abstract
Optimization of neem oil extraction using Central Composite Design (CCD) was evaluated in this research. The effects of two factors: sample weight and extraction duration on the response which is neem oil volume extracted, were investigated. The CCD employed resulted in 13 experimental runs. Extraction was carried out in a 250 ml Soxhlet extractor. Hexane was used as solvent with thermostated heating mantle at temperature 60°C. Results obtained shows the optimized values of 54.69% of neem oil was obtained with 25 g weight of sample with extraction time of 12hours. Ther2andr2adjvalues were close to 1 which indicates that the regression model was a good one.

This publication has 21 references indexed in Scilit: