Assessing the Accuracy of Non-Rigid Registration With and Without Ground Truth
Authors:
- T. CootesTCT. Cootes
- W.R. CrumWCW.R. Crum
- 1 January 2006
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19457928,p. 836-839
Abstract
We compare two methods for assessing the performance of groupwise non-rigid registration algorithms. The first approach, which has been described previously, utilizes a measure of overlap between ground-truth anatomical labels. The second, which is new, exploits the fact that, given a set of nonrigidly registered images, a generative statistical model of appearance can be constructed. We observe that the quality of this model depends on the quality of the registration, and define measures of model specificity and generalisation - based on comparing synthetic images sampled from the model, with those in the original image set - that can be used to assess model/registration quality. We show that both approaches detect the loss of registration accuracy as the alignment of a set of correctly registered MR images of the brain is progressively perturbed. We compare the sensitivities of the two approaches and show that, as well as requiring no ground truth, specificity provides the most sensitive measure of misregistrationKeywords
This publication has 13 references indexed in Scilit:
- A Unified Information-Theoretic Approach to Groupwise Non-rigid Registration and Model BuildingLecture Notes in Computer Science, 2005
- Generalised Overlap Measures for Assessment of Pairwise and Groupwise Image Registration and SegmentationLecture Notes in Computer Science, 2005
- Non-rigid image registration: theory and practiceBritish Journal of Radiology, 2004
- Image registration methods: a surveyImage and Vision Computing, 2003
- Fame-a flexible appearance modeling environmentIEEE Transactions on Medical Imaging, 2003
- Automatic construction of 3-D statistical deformation models of the brain using nonrigid registrationIEEE Transactions on Medical Imaging, 2003
- Automatic construction of multiple-object three-dimensional statistical shape models: application to cardiac modelingIEEE Transactions on Medical Imaging, 2002
- A minimum description length approach to statistical shape modelingIEEE Transactions on Medical Imaging, 2002
- Validation of Non-rigid Registration Using Finite Element Methods2001
- Nonrigid registration using free-form deformations: application to breast MR imagesIEEE Transactions on Medical Imaging, 1999