Initial Clinical Experience Treating Patients With Lung Cancer on a 6MV-Flattening-Filter-Free O-Ring Linear Accelerator
Authors:
- Andrew R. BarskyABAndrew R. Barsky
- Hui LinHLHui Lin
- Amberly MendesAMAmberly Mendes
- Alexandra DreyfussADAlexandra Dreyfuss
- Christopher WrightCWChristopher Wright
- Emily J. AnstadtEAEmily J. Anstadt
- Abigail T. BermanABAbigail T. Berman
- William P. LevinWLWilliam P. Levin
- Keith A CengelKCKeith A Cengel
- Nathan AndersonNANathan Anderson
- Lei DongLDLei Dong
- James M. MetzJMJames M. Metz
Open Access
- 9 September 2020
- journal article
- research article
- Published by Springer Nature in Cureus
- Vol. 12 (9)
Abstract
Introduction Modern technologies, like intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT), have improved the therapeutic ratio of thoracic radiotherapy (TRT) for lung cancer (LC). Halcyon (TM) (Varian Medical Systems, Palo Alto, CA, USA), a novel 6MV-flattening-filter-free O-ring linear accelerator (6X-FFF ORL), was designed to deliver IMRT and VMAT with greater speed than a C-arm linac. Herein, we report our initial clinical experience treating patients with LC on this linac. Methods All patients who received TRT for LC on the 6X-FFF ORL at our institution were retrospectively identified. Patients' clinicopathologic data, radiotherapy details, early disease-control and toxicity outcomes, dosimetric data, couch corrections, and treatment times are reported. Results Between 10/2018-12/2019, 30 consecutive patients (median age 66 years, range 54-94 years) received definitive or post-operative TRT for LC (median 66 Gy/33 fractions; range 5-70 Gy/237 fractions) following four-dimensional computed tomography (CT) simulation (97%) using daily kilovoltage KV cone-beam CT (CBCT) (100%) on a 6X-FFF ORL for non-small cell LC (84%) or small cell LC (16%), with 53% receiving VMAT, 43% receiving static-field IMRT, and 77% receiving concurrent systemic therapy. All plans were approved through institutional peer review. The average three-dimensional vector couch correction based on CBCT guidance was 0.90 +/- 0.50 cm. The average beam-on and beam on plus CBCT times were 1.7 +/- 1.1 min, and 5.0 +/- 3.2 min, respectively. Grade 3 dyspnea and fatigue occurred in 3% and 3% of patients, respectively. There were no grade >= 4 toxicities. Conclusion In this first clinical report of TRT for LC on a 6X-FFF ORL, daily CBCT-guided treatment was fast and safe with respect to dosimetry and clinical outcomes. Thus, use of this linac for TRT may increase LC patient throughput without a detriment in radiotherapy quality.Keywords
This publication has 27 references indexed in Scilit:
- Impact of Intensity-Modulated Radiation Therapy Technique for Locally Advanced Non–Small-Cell Lung Cancer: A Secondary Analysis of the NRG Oncology RTOG 0617 Randomized Clinical TrialJournal of Clinical Oncology, 2017
- Use of thoracic radiotherapy for extensive stage small-cell lung cancer: a phase 3 randomised controlled trialThe Lancet, 2015
- Definitive Reirradiation for Locoregionally Recurrent Non-Small Cell Lung Cancer With Proton Beam Therapy or Intensity Modulated Radiation Therapy: Predictors of High-Grade Toxicity and Survival OutcomesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2014
- Assessing the Role of Volumetric Modulated Arc Therapy (VMAT) Relative to IMRT and Helical Tomotherapy in the Management of Localized, Locally Advanced, and Post-Operative Prostate CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- Meta-Analysis of Concomitant Versus Sequential Radiochemotherapy in Locally Advanced Non–Small-Cell Lung CancerJournal of Clinical Oncology, 2010
- Tumor Localization Using Cone-Beam CT Reduces Setup Margins in Conventionally Fractionated Radiotherapy for Lung TumorsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Comparison of Spine, Carina, and Tumor as Registration Landmarks for Volumetric Image-Guided Lung RadiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- The characterization of unflattened photon beams from a 6 MV linear acceleratorPhysics in Medicine & Biology, 2008
- Testing of the analytical anisotropic algorithm for photon dose calculationMedical Physics, 2006
- Twice-Daily Compared with Once-Daily Thoracic Radiotherapy in Limited Small-Cell Lung Cancer Treated Concurrently with Cisplatin and EtoposideNew England Journal of Medicine, 1999