A Clinical Comparison of the Flexiblade™ and Macintosh Laryngoscopes for Laryngeal Exposure in Anesthetized Adults
Authors:
- Rochelle W. W. CheungRCRochelle W. W. Cheung
- Michael G. IrwinMIMichael G. Irwin
- Bassanio C. W. LawBLBassanio C. W. Law
- C K. ChanCCC K. Chan
- 1 February 2006
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 102 (2) , 626-630
Abstract
The Flexiblade is a laryngoscope with a flexible blade. To evaluate the efficacy of the Flexiblade compared with the classic Macintosh laryngoscope, we performed a clinical study in 200 paralyzed patients undergoing elective surgery requiring general anesthesia and endotracheal intubation. Direct laryngoscopy was performed with a size 3 Macintosh laryngoscope and the Flexiblade, with and without activation of the lever. The laryngeal views were recorded, without manipulation, according to the Cormack and Lehane classification. No laryngoscopic view obtained by the Macintosh blade was worse than that obtained by the Flexiblade without the lever activated. The Macintosh blade improved 58.5% of non-Grade I views obtained by the Flexiblade with its lever not activated. However, when the Flexiblade lever was activated, 39.6% of non-Grade I views obtained by the Macintosh blade were improved, whereas 84.5% of non-Grade I views obtained by the inactivated Flexiblade were improved. Activating the Flexiblade lever never caused a deterioration of view. In only one case was the view better with the Macintosh blade than that with the activated Flexiblade. We conclude that the Flexiblade, after lever activation, is significantly better than the Macintosh laryngoscope for laryngeal visualization in paralyzed adults (P < 0.0001).Keywords
This publication has 13 references indexed in Scilit:
- Straight blades improve visualization of the larynx while curved blades increase ease of intubation: a comparison of the Macintosh, Miller, McCoy, Belscope and Lee-Fiberview bladesCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2003
- Design evaluation of commonly used rigid and levering laryngoscope bladesActa Anaesthesiologica Scandinavica, 2002
- Evaluation of the use of the FlexibladeAnaesthesia, 2000
- A new laryngoscope with flexible adjustable rigid bladeBritish Journal of Anaesthesia, 1999
- Difficult laryngoscopy made easy with a “BURP”Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 1993
- An analysis of laryngoscope blade shape and design: new criteria for laryngoscope evaluationCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1993
- An evaluation of the gum elastic bougieAnaesthesia, 1992
- Criteria for Estimating Likelihood of Difficulty of Endotracheal Intubation with the Macintosh LaryngoscopeAnaesthesia and Intensive Care, 1988
- A clinical sign to predict difficult tracheal intubation; a prospective studyCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1985
- Difficult tracheal intubation in obstetricsAnaesthesia, 1984