Inkjet Printed Multi‐walled Carbon Nanotube Sensor for the Detection of Lead in Drinking Water
Authors:
- 25 March 2020
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 32 (7) , 1533-1545
Abstract
Electroanalytical methods can be used for the reliable detection of the toxic heavy metal lead in drinking water samples. Inkjet printed electrodes have potential for the rapid and affordable assessment of drinking water. Researchers have shown the electrochemical sensing applicability of inkjet printed electrodes. In this work, Pb2+ was detected using an inkjet printed multi‐walled carbon nanotube (IJP‐MW‐CNT) electrode with silver tracks printed underneath. The silver tracks provide the sensor with the conductivity needed for sensitive measurements. MW‐CNT were dispersed in water using bile salts as a surfactant to prepare the ink. The IJP‐MW‐CNT electrode was used as the working electrode with a platinum wire and Ag/AgCl as auxiliary and reference electrode, respectively. The electrodes performance was optimized in 0.1 M acetate buffer (pH=4.3) and had two linear ranges of 5 to 20 ppb (R2=0.99) with a sensitivity of 38 nA/ppb and 20 to 50 ppb (R2=0.98) with a sensitivity of 15 nA/ppb and a limit of detection (LOD) of 1.0 ppb for Pb2+. The analytical applicability of electrode was determined by constructing a calibration curve in an unaltered drinking water sample (i. e.) Cincinnati tap water with two linear ranges of 15 to 40 ppb (R2=0.99) with a sensitivity of 1.5 nA/ppb and 40 to 70 ppb (R2=0.99) with a sensitivity of 3.5 nA/ppb and a LOD of 1.0 ppb for Pb2+. Effects of copper and cadmium as potential interferents are reported.Keywords
Funding Information
- University of Cincinnati Professorship Startup Funds
This publication has 74 references indexed in Scilit:
- β-Galactosidase-Based Colorimetric Paper Sensor for Determination of Heavy MetalsAnalytical Chemistry, 2011
- Determination of Trace Metals by Anodic Stripping Voltammetry Using a Carbon Nanotube Tower ElectrodeElectroanalysis, 2011
- Effects of Lead and Mercury on the Blood Proteome of ChildrenJournal of Proteome Research, 2010
- Individual and simultaneous determination of lead, cadmium, and zinc by anodic stripping voltammetry at a bismuth bulk electrodeTalanta, 2010
- Determination of trace heavy metals in herbs by sequential injection analysis-anodic stripping voltammetry using screen-printed carbon nanotubes electrodesAnalytica Chimica Acta, 2010
- Detection of Trace Heavy Metal Ions Using Carbon Nanotube‐ Modified ElectrodesElectroanalysis, 2009
- The renovated silver ring electrode in determination of lead traces by differential pulse anodic stripping voltammetryAnalytica Chimica Acta, 2008
- Nafion/Poly(sodium 4‐styrenesulfonate) Mixed Coating Modified Bismuth Film Electrode for the Determination of Trace Metals by Anodic Stripping VoltammetryElectroanalysis, 2007
- A comparison of boron-doped diamond thin-film and Hg-coated glassy carbon electrodes for anodic stripping voltammetric determination of heavy metal ions in aqueous mediaAnalytica Chimica Acta, 2006
- Potential-pH Diagram of Lead and its Applications to the Study of Lead Corrosion and to the Lead Storage BatteryJournal of the Electrochemical Society, 1951