Clinical characteristics and outcomes of patients requiring prolonged inotropes after left ventricular assist device implantation
Authors:
- Jose B. Cruz RodriguezJRJose B. Cruz Rodriguez
- Garrick C. StewartGSGarrick C. Stewart
- Jose A. TallajJTJose A. Tallaj
- Indranee RajapreyarIRIndranee Rajapreyar
- James K. KirklinJKJames K. Kirklin
- William L. HolmanWHWilliam L. Holman
- Debabrata MukherjeeDMDebabrata Mukherjee
- Indika MallawaarachchiIMIndika Mallawaarachchi
- Alok DwivediADAlok Dwivedi
- Deepak AcharyaDADeepak Acharya
- 3 April 2020
- journal article
- research article
- Published by Wiley in Artificial Organs
- Vol. 44 (10) , E382-E393
Abstract
Limited data exist regarding patients with continuous‐flow left ventricular assist device (LVAD) support who require long‐term inotropes. Our primary objective was to evaluate the clinical characteristics and all‐cause mortality of LVAD recipients with prolonged inotrope use (PIU). Secondary endpoints were to compare predictors of PIU, mortality, risk of late re‐initiation of inotropes, time to gastrointestinal bleed (GIB), infection, and arrhythmias. Retrospective cohort study was conducted on adult patients with primary continuous‐flow LVADs implanted from January 2008 to February 2017 and the patients were followed up through February 2018. We defined PIU as ≥14 days of inotrope support. Kaplan–Meier method, competing risk models and Cox proportional hazard models were used. Final analytic sample was 203 patients, 58% required PIU, and 10% were discharged on inotropes. There was no difference in preimplant characteristics. One‐year survival rate was 87% if no PIU required, 74% if PIU required, and 72% if discharged on inotropes. PIU was associated with longer length of stay and higher incidence of GIB. We found no association between PIU and late re‐initiation of inotropes, infection or arrhythmias. Adjusted hazard risk of death was increased in patients with PIU (HR = 1.66, P = .046), older age (HR = 1.28, P = .031), and higher creatinine levels (HR = 1.60, P = .007). Prolonged inotrope use is frequently encountered following LVAD implantation and is associated with adverse prognosis but remains a therapeutic option. Inability to wean inotropes prior to hospital discharge is a marker of patients at particularly higher risk of mortality following LVAD implantation.Keywords
Funding Information
- Texas Tech University
This publication has 28 references indexed in Scilit:
- The 2013 International Society for Heart and Lung Transplantation Guidelines for mechanical circulatory support: Executive summaryThe Journal of Heart and Lung Transplantation, 2013
- Postoperative Right Ventricular Failure After Left Ventricular Assist Device Placement is Predicted by Preoperative Echocardiographic Structural, Hemodynamic, and Functional ParametersJournal of Cardiac Failure, 2013
- Right ventricular failure after LVAD implantation: Prevention and treatmentBest Practice & Research Clinical Anaesthesiology, 2012
- Liver dysfunction as a predictor of outcomes in patients with advanced heart failure requiring ventricular assist device support: Use of the Model of End-stage Liver Disease (MELD) and MELD eXcluding INR (MELD-XI) scoring systemThe Journal of Heart and Lung Transplantation, 2012
- Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: Incidence, risk factors, and effect on outcomesThe Journal of Thoracic and Cardiovascular Surgery, 2010
- Risk Factors Predictive of Right Ventricular Failure After Left Ventricular Assist Device ImplantationThe American Journal of Cardiology, 2010
- Advanced Heart Failure Treated with Continuous-Flow Left Ventricular Assist DeviceThe New England journal of medicine, 2009
- Early planned institution of biventricular mechanical circulatory support results in improved outcomes compared with delayed conversion of a left ventricular assist device to a biventricular assist deviceThe Journal of Thoracic and Cardiovascular Surgery, 2009
- Post-Heart Transplant Diastolic Dysfunction Is a Risk Factor for MortalityJACC, 2007
- Duration of inotropic support after left ventricular assist device implantation: Risk factors and impact on outcomeThe Journal of Thoracic and Cardiovascular Surgery, 2006