Multiple graft injury due to migrated nonbroken sternal wires 2 years after cardiac surgery
- 2 June 2020
- journal article
- editorial
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 35 (7) , 1640-1641
Abstract
The migration of sternal wires into vital structures is a rare but potentially life‐threatening complication and associated with infection in some cases. While a few cases have been reported the sternal wires were broken in those cases. To our knowledge, this is the first report of multiple, nonbroken, migrated sternal wires stabbing vascular grafts.Keywords
This publication has 4 references indexed in Scilit:
- Management of thoracic aortic graft infectionsJournal of Cardiac Surgery, 2018
- Ascending aortic injury caused by a fractured sternal wire 28 years after surgical intervention of pectus excavatumThe Journal of Thoracic and Cardiovascular Surgery, 2009
- When a snapped sternal wire stabbed the aortaEuropean Journal of Cardio-Thoracic Surgery, 2008
- Migration of sternal wire into ascending aortaThe Annals of Thoracic Surgery, 1994