Abstract
During image-guided prostate biopsy, needles are targeted at suspicious tissues to obtain specimens that are later examined histologically for cancer. Patient motion causes inaccuracies when using MR-transrectal ultrasound (TRUS) image fusion approaches used to augment the conventional biopsy procedure. Motion compensation using a single, user initiated correction can be performed to temporarily compensate for prostate motion, but a real-time continuous registration offers an improvement to clinical workflow by reducing user interaction and procedure time. An automatic motion compensation method, approaching the frame rate of a TRUS-guided system, has been developed for use during fusion-based prostate biopsy to improve image guidance. 2D and 3D TRUS images of a prostate phantom were registered using an intensity based algorithm utilizing normalized cross-correlation and Powell’s method for optimization with user initiated and continuous registration techniques. The user initiated correction performed with observed computation times of 78 ± 35 ms, 74 ± 28 ms, and 113 ± 49 ms for in-plane, out-of-plane, and roll motions, respectively, corresponding to errors of 0.5 ± 0.5 mm, 1.5 ± 1.4 mm, and 1.5 ± 1.6°. The continuous correction performed significantly faster (p < 0.05) than the user initiated method, with observed computation times of 31 ± 4 ms, 32 ± 4 ms, and 31 ± 6 ms for in-plane, out-of-plane, and roll motions, respectively, corresponding to errors of 0.2 ± 0.2 mm, 0.6 ± 0.5 mm, and 0.8 ± 0.4°. © (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.Keywords
This publication has 19 references indexed in Scilit:
- Multiattribute probabilistic prostate elastic registration (MAPPER): Application to fusion of ultrasound and magnetic resonance imagingMedical Physics, 2015
- Simulated required accuracy of image registration tools for targeting high-grade cancer components with prostate biopsiesEuropean Radiology, 2012
- MR to ultrasound registration for image-guided prostate interventionsMedical Image Analysis, 2012
- 3-Dimensional Elastic Registration System of Prostate Biopsy Location by Real-Time 3-Dimensional Transrectal Ultrasound Guidance With Magnetic Resonance/Transrectal Ultrasound Image FusionJournal of Urology, 2012
- A Novel Stereotactic Prostate Biopsy System Integrating Pre-Interventional Magnetic Resonance Imaging and Live Ultrasound FusionJournal of Urology, 2011
- Upgrading the Gleason Score in Extended Prostate Biopsy: Implications for Treatment ChoiceInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Mechanically assisted 3D ultrasound guided prostate biopsy systemMedical Physics, 2008
- Design and evaluation of a 3D transrectal ultrasound prostate biopsy systemMedical Physics, 2008
- Real-time MRI-TRUS fusion for guidance of targeted prostate biopsiesComputer Aided Surgery, 2008
- INCIDENCE AND CLINICAL SIGNIFICANCE OF FALSE-NEGATIVE SEXTANT PROSTATE BIOPSIESJournal of Urology, 1998