Calibration of Correlation Radiometers Using Pseudo-Random Noise Signals
Authors:
- Isaac Ramos PérezIPIsaac Ramos Pérez
- Xavi Bosch-LluisXBXavi Bosch-Lluis
- Adriano CampsACAdriano Camps
- Nereida Rodriguez AlvarezNANereida Rodriguez Alvarez
- Juan F. Marchán HernandezJHJuan F. Marchán Hernandez
- Enric Valencia DomènechEDEnric Valencia Domènech
- Carlos VernichCVCarlos Vernich
- Sonia De la RosaSRSonia De la Rosa
- Sebastián PantojaSPSebastián Pantoja
Open Access
Abstract
The calibration of correlation radiometers, and particularly aperture synthesis interferometric radiometers, is a critical issue to ensure their performance. Current calibration techniques are based on the measurement of the cross-correlation of receivers’ outputs when injecting noise from a common noise source requiring a very stable distribution network. For large interferometric radiometers this centralized noise injection approach is very complex from the point of view of mass, volume and phase/amplitude equalization. Distributed noise injection techniques have been proposed as a feasible alternative, but are unable to correct for the so-called “baseline errors” associated with the particular pair of receivers forming the baseline. In this work it is proposed the use of centralized Pseudo-Random Noise (PRN) signals to calibrate correlation radiometers. PRNs are sequences of symbols with a long repetition period that have a flat spectrum over a bandwidth which is determined by the symbol rate. Since their spectrum resembles that of thermal noise, they can be used to calibrate correlation radiometers. At the same time, since these sequences are deterministic, new calibration schemes can be envisaged, such as the correlation of each receiver’s output with a baseband local replica of the PRN sequence, as well as new distribution schemes of calibration signals. This work analyzes the general requirements and performance of using PRN sequences for the calibration of microwave correlation radiometers, and particularizes the study to a potential implementation in a large aperture synthesis radiometer using an optical distribution network.Keywords
This publication has 16 references indexed in Scilit:
- SMOS CalibrationIEEE Transactions on Geoscience and Remote Sensing, 2008
- A correlated noise calibration standard for interferometric, polarimetric, and autocorrelation microwave radiometersIEEE Transactions on Geoscience and Remote Sensing, 2003
- Redundant space calibration of hexagonal and Y-shaped beamforming radars and interferometric radiometersInternational Journal of Remote Sensing, 2003
- How digital correlation affects the fringe washing function in L-band aperture synthesis radiometryIEEE Transactions on Geoscience and Remote Sensing, 2002
- Analysis of noise-injection networks for interferometric-radiometer calibrationIEEE Transactions on Microwave Theory and Techniques, 2000
- Automatic calibration of channels frequency responsein interferometric radiometersElectronics Letters, 1999
- Impact of receiver errors on the radiometric resolution of large two‐dimensional aperture synthesis radiometersRadio Science, 1997
- On-board phase and modulus calibration of large aperture synthesis radiometers: study applied to MIRASIEEE Transactions on Geoscience and Remote Sensing, 1996
- Digital‐correlation techniques in radio scienceRadio Science, 1973
- Optimal binary sequences for spread spectrum multiplexing (Corresp.)IEEE Transactions on Information Theory, 1967