The performance of different anti-dsDNA autoantibodies assays in Chinese systemic lupus erythematosus patients
Authors:
- 25 July 2017
- journal article
- research article
- Published by Springer Nature in Clinical Rheumatology
- Vol. 37 (1) , 139-144
Abstract
To compare the performance of different commercial anti-dsDNA autoantibody assays, including multiplex-based immunoassay (Bio-Plex), Farr radioimmunoassay (Farr), ELISA, chemiluminescent immunoassay (CLIA), and Crithidia Luciliae indirect immunofluorescence test (CLIFT) in Chinese patients with systemic lupus erythematosus (SLE). SLE patients (n = 119) as well as healthy controls (n = 200) and disease controls (n = 100) were recruited, and serum anti-dsDNA autoantibodies were detected by Bio-Plex, Farr, two ELISA assays (Medical & Biological Laboratories-ELISA, EUROIMMU-ELISA), CLIA, and a standard CLIFT. The correlation of anti-dsDNA autoantibody levels to SLE disease activity was calculated, and the specificity and sensitivity of these methods were measured by receiver-operator characteristic (ROC) curve analysis. In ROC curve analysis, Bio-Plex showed the largest area under the curve (AUC) over other assays. Cutoff adjustment according to ROC enhanced the performance of all quantitative assays. Overall, Bio-Plex and CLIFT have higher specificity (>90.00%). ELISA and CLIA results are correlated with disease activity, and Bio-Plex results have the strongest correlation with SLEDAI score and active renal involvement. Bio-Plex assay has better overall performance in anti-dsDNA detection over Farr, ELISA, and CLIA methods in Chinese SLE patients.Keywords
Funding Information
- National Natural Science Foundation of China (81601402)
This publication has 21 references indexed in Scilit:
- Clinical performance evaluation of a novel rapid response chemiluminescent immunoassay for the detection of autoantibodies to extractable nuclear antigensClinica Chimica Acta, 2013
- BioPlex™ 2200 multiplexed system: Simultaneous detection of anti-dsDNA and anti-chromatin antibodies in patients with systemic lupus erythematosusAutoimmunity, 2009
- Evaluation of the BioPlex 2200 ANA Screen for the Detection of Antinuclear Antibodies and Comparison with Conventional MethodsAnnals of the New York Academy of Sciences, 2007
- Evaluation of Current Methods for the Measurement of Serum Anti–Double‐Stranded DNA AntibodiesAnnals of the New York Academy of Sciences, 2007
- Anti-dsDNA antibody testing in the clinic: Farr or ELISA?Nature Clinical Practice Rheumatology, 2007
- Updating the American college of rheumatology revised criteria for the classification of systemic lupus erythematosusArthritis & Rheumatism, 1997
- Autoantibody profile in African-American patients with lupus nephritisLupus, 1996
- Measurement of anti-DNA antibodies: a reappraisal using five different methods.Annals of the Rheumatic Diseases, 1987
- The 1982 revised criteria for the classification of systemic lupus erythematosusArthritis & Rheumatism, 1982
- Antibodies against Double‐Stranded DNA in Patients with Connective Tissue DiseasesActa Medica Scandinavica, 1978