Clinical Practices in Central Venous Catheter Mechanical Adverse Events
- 20 June 2022
- journal article
- research article
- Published by SAGE Publications in Journal of Intensive Care Medicine
- Vol. 37 (9) , 1215-1222
Abstract
Background: Over 5 million central venous catheters (CVCs) are placed annually. Pneumothorax and catheter malpositioning are common adverse events (AE) that requires attention. This study aims to evaluate local practices of mechanical complication frequency, type, and subsequent intervention(s) related to mechanical AE with an emphasis on catheter malpositioning. Methods: This is a retrospective review of CVC placements in a tertiary hospital setting from 1/2013 to 12/2013. Pneumothorax and CVC positioning were evaluated on post-insertion chest x-ray (CXR). Malposition was defined as unintended placement of the catheter in a vessel other than the intended superior vena cava on CXR. Catheter reposition was defined as radiographic evidence of a new catheter with removal of the old catheter less than 24hrs after initial placement. Data points analyzed included pneumothorax and thoracostomy rate, CVC malposition frequency, catheter reposition rate, catheter duration, and incidence of complications such as catheter associated venous thrombosis. Result: Among 2045 eligible CVC insertions, pneumothoraces occurred in 14 (0.7%; 95%CI 0.38, 1.17) and malpositions were identified in 275 (13.4%; 95% CI 12.3, 15.3). The proportion of pneumothoraces that required tube thoracostomy was 57%. The proportion of CVCs with malposition that were removed or replaced within 24h was 32.7%. "Malpositioned" catheters that were left in place by the clinical team (n = 185) had an average catheter duration of 8.2 days (95% CI 7.2, 9.3) versus 7.2 days (95% CI 6.17, 8.23) for catheters that were replaced after initial malposition (p = 0.14, t test). The incidence of venous thrombosis in repositioned “malpositioned” catheters was 7.8% versus 4.9% for “malpositioned” catheters that were left in place. Conclusions: Clinically significant catheter malposition and pneumothorax after CVC insertion are low. In this study, replaced and non-replaced “malpositioned” catheters had similar catheter duration and rates of complications, challenging the current dogma of CVC malposition practice.Keywords
Funding Information
- National Heart, Lung, and Blood Institute (K12HL137942-02)
This publication has 32 references indexed in Scilit:
- Vascular Complications of Central Venous Catheter Placement: Evidence-Based Methods for Prevention and TreatmentJournal of Cardiothoracic and Vascular Anesthesia, 2014
- Safe Placement of Central Venous CathetersJournal of Intensive Care Medicine, 2011
- Risk Factors for Acute Adverse Events During Ultrasound‐guided Central Venous Cannulation in the Emergency DepartmentAcademic Emergency Medicine, 2010
- Precision in Central Venous Catheter Tip Placement: A Review of the LiteratureJournal of the Association for Vascular Access, 2010
- Ultrasound-guided central venous catheter placement decreases complications and decreases placement attempts compared with the landmark technique in patients in a pediatric intensive care unit*Critical Care Medicine, 2009
- The Society for Vascular Surgery: Clinical practice guidelines for the surgical placement and maintenance of arteriovenous hemodialysis accessJournal of Vascular Surgery, 2008
- Ultrasound guidance for placement of central venous cathetersCritical Care Medicine, 1996
- Chart Reviews In Emergency Medicine Research: Where Are The Methods?Annals of Emergency Medicine, 1996
- Facilitation of internal jugular venous cannulation using an audio-guided Doppler ultrasound vascular access deviceCritical Care Medicine, 1995
- Accurate placement of central venous cathetersCritical Care Medicine, 1993