Estimation of Arterial Blood Pressure Waveform from Photoplethysmogram Signal using Linear Transfer Function Approach
Authors:
- 1 July 2020
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2020, 2691-2694
Abstract
The primary risk factor of hypertension, is the lack of awareness caused by the unavailability of ubiquitous blood pressure (BP) measurement. In this study, we have investigated the BP estimation using the photoplethysmogram (PPG) signal and a suitable subject-specific mathematical model. The linear transfer function (LTF) technique was used to identify the subject-specific model. Firstly, we tried to identify the model considering arterial blood pressure (ABP) as input and PPG as output, and we achieved an average estimation accuracy (normalized root mean square, NRMSE) of 84.4%. Next, we fitted an inverse model, where ABP is the output, and PPG is the input, and we achieved an average estimation accuracy (NRMSE) of 84.7%. Finallly, We verified that the two identified models mentioned above are inverse of each other. In this study, we have used ABP and PPG signals of 10 (male = 7, female = 3) subjets from the MIMIC II database. The results are quite promising for the use of the PPG in the detection and diagnosis of cardiovascular diseases.Keywords
This publication has 17 references indexed in Scilit:
- Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and PracticeIEEE Transactions on Biomedical Engineering, 2015
- A comparative risk assessment of burden of disease and injury attributable to 67 risk factors and risk factor clusters in 21 regions, 1990–2010: a systematic analysis for the Global Burden of Disease Study 2010The Lancet, 2012
- Cuffless Differential Blood Pressure Estimation Using Smart PhonesIEEE Transactions on Biomedical Engineering, 2012
- The arterial WindkesselMedical & Biological Engineering & Computing, 2008
- Photoplethysmography and its application in clinical physiological measurementPhysiological Measurement, 2007
- MIMIC II: a massive temporal ICU patient database to support research in intelligent patient monitoring2002
- Blood pressure measuring devices: recommendations of the European Society of HypertensionBMJ, 2001
- Modelling the relationship between peripheral blood pressure and blood volume pulses using linear and neural network system identification techniquesPhysiological Measurement, 1999
- Total arterial inertance as the fourth element of the windkessel modelAmerican Journal of Physiology-Heart and Circulatory Physiology, 1999
- Arterial tonometry: Review and analysisJournal of Biomechanics, 1983