Skin dose rate conversion factors after contamination with radiopharmaceuticals: influence of contamination area, epidermal thickness and percutaneous absorption
Authors:
- P CovensPCP Covens
- D BerusDBD Berus
- V CaveliersVCV Caveliers
- L StruelensLSL Struelens
- F VanhavereFVF Vanhavere
- D VerellenDVD Verellen
- 1 March 2013
- journal article
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 33 (2) , 381-393
Abstract
Skin contamination with radiopharmaceuticals can occur during biomedical research and daily nuclear medicine practice as a result of accidental spills, after contact with bodily fluids of patients or by inattentively touching contaminated materials. Skin dose assessment should be carried out by repeated quantification to map the course of the contamination together with the use of appropriate skin dose rate conversion factors. Contamination is generally characterised by local spots on the palmar surface of the hand and complete decontamination is difficult as a result of percutaneous absorption. This specific issue requires special consideration as to the skin dose rate conversion factors as a measure for the absorbed dose rate to the basal layer of the epidermis. In this work we used Monte Carlo simulations to study the influence of the contamination area, the epidermal thickness and the percutaneous absorption on the absorbed skin dose rate conversion factors for a set of 39 medical radionuclides. The results show that the absorbed dose to the basal layer of the epidermis can differ by up to two orders of magnitude from the operational quantity Hp(0.07) when using an appropriate epidermal thickness in combination with the effect of percutaneous absorption.Keywords
This publication has 18 references indexed in Scilit:
- Skin contamination of nuclear medicine technologistsNuclear Medicine Communications, 2012
- The contribution of skin contamination dose to the total extremity dose of nuclear medicine staff: First results of an intensive surveyRadiation Measurements, 2011
- Hand exposure in diagnostic nuclear medicine with 18F- and 99mTc-labelled radiopharmaceuticals - Results of the ORAMED projectRadiation Measurements, 2011
- Skin contamination by radiopharmaceuticals and decontamination strategiesInternational Journal of Pharmaceutics, 2010
- The introduction of automated dispensing and injection during PET procedures: a step in the optimisation of extremity doses and whole-body doses of nuclear medicine staffRadiation Protection Dosimetry, 2010
- Personal dose monitoring in hospitals: global assessment, critical applications and future needsRadiation Protection Dosimetry, 2007
- The skin in radiological protection--recent advances and residual unresolved issuesRadiation Protection Dosimetry, 2004
- A study of doses to the hands during dispensing of radiopharmaceuticalsNuclear Medicine Communications, 2000
- Comparisons between MCNP, EGS4 and experiment for clinical electron beamsPhysics in Medicine & Biology, 1999
- ITS: the integrated TIGER series of electron/photon transport codes-Version 3.0IEEE Transactions on Nuclear Science, 1992