Engineering patient-specific drill templates and bioabsorbable posterior cervical plates: a feasibility study
- 1 February 2009
- journal article
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 10 (2) , 129-132
Abstract
Object: The authors describe a method of using computer models to generate customized cervical implants. A promising yet challenging technique in cervical spine surgery involves the use of pedicle screws to assist with posterior instrumentation. Surrounding anatomical structures such as the vertebral arteries and cervical nerve roots present challenges for safe screw placement; however, the use of computer-generated templates seems to be a promising method to assist with placement. In this study, the authors explore the use of computer-generated templates and introduce their methods for creating custom, bioabsorbable posterior cervical implants. Methods: The cervical spines (C2–T1) from 4 cadavers were scanned with volumetric CT. Using commercially available software, the authors generated volumetric models of a cervical drill template and the mold for a cervical plate spanning a desired number of vertebrae. The computer generated models of the cervical drill template and cervical plate mold were converted into physical models using a rapid prototyping machine. The biopolymer polylactic acid resin was heated to 250°C and resolidified to form thin ~ 5-mm-thick plates. The newly formed plates were reheated to 60°C and cast on the cervical mold. Results: The resulting translucent plates were found on visual inspection to have a secure lock-and-key fit on the original cadaver spine, and the techniques used were robust and reproducible. The process described in this brief report provides the background to proceed with development and testing of these patient-absorbable templates. Conclusions: The creation and use of patient-specific bioabsorbable posterior cervical plates in conjunction with multilevel drill templates appear promising. Additional feasibility studies are planned, and in vitro studies are required to determine the safety and efficacy of using patient-specific drill templates and converting them into bioabsorbable implants.Keywords
This publication has 17 references indexed in Scilit:
- Rapid prototype patient-specific drill template for cervical pedicle screw placementComputer Aided Surgery, 2007
- Spinous process plate fixation as a salvage operation for failed anterior cervical fusionJournal of Neurosurgery: Spine, 2006
- Biomechanical analysis of a newly designed bioabsorbable anterior cervical plateJournal of Neurosurgery: Spine, 2005
- Complications of transpedicular screw fixation in the cervical spineEuropean Spine Journal, 2005
- Evaluation of a transpedicular drill guide for pedicle screw placement in the thoracic spineEuropean Spine Journal, 2003
- Cervical Pedicle Screws Versus Lateral Mass ScrewsSpine, 1997
- New bioresorbable pin for the reduction of small bony fragments: design, mechanical properties and in vitro degradationBiomaterials, 1996
- Spinal Pedicle FixationSpine, 1993
- Preliminary report on the osteogenic potential of a biodegradable copolymer of polyactide (PLA) and polyglycolide (PGA)Journal of Biomedical Materials Research, 1983
- Evaluation and comparisons of biodegradable substances as osteogenic agentsOral Surgery, Oral Medicine, Oral Pathology, 1977