Power Loss and Thermal Temperature Calculation of IGBT Module by Mathematical Equations
Authors:
- 24 February 2023
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 862-867
Abstract
Today, inverters are used in many industrial applications such as battery systems, fuel cells, solar cells, wind turbines, motor drives and uninterruptible power supplies. There are semiconductor switches in the structure of the inverters. Most of the inverter losses occur on semiconductor switches. If the losses in the semiconductor switches are calculated correctly, the heatsink can be selected appropriately. In this study, the conduction losses, switching losses and thermal temperature values of the two-level neutral point inverter with a power of 20kVA were calculated using mathematical equations and Fuji IGBT simulator program. During the calculations, manufacturer catalog data of IGBT module and heatsink were used. The calculations were made at ambient temperature of 25°C and the inverter was operated under 40% and 100% load. The results were given using figures and tables.Keywords
This publication has 5 references indexed in Scilit:
- The Effect of Temperature Changes on Semiconductor Material Efficiency Under Load2022
- A New Approach for Power Losses Evaluation of IGBT/Diode ModuleElectronics, 2021
- Three-phase voltage source inverter using SiC MOSFETs — Design and Optimization2015
- A power loss characterization method for semiconductor switching devices based on inverter-level DC measurements2014
- Power loss analysis of five-level inverters for grid tie photovoltaic system2013