Catecholamine Interference in Enzymatic Creatinine Assays
Open Access
- 1 September 2009
- journal article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 55 (9) , 1732-1736
Abstract
Background: Enzymatic creatinine assays are routinely used in clinical laboratories to provide more accurate estimated glomerular filtration rates and to avoid a perceived lack of analytical specificity associated with picrate (Jaffe) methods. Negative interferences with the enzymatic creatinine assay, which we noted in several patients on dopamine or dobutamine, prompted our further investigation into interference of catecholamines with enzymatic methods. Methods: Spiked solutions of dopamine, dobutamine, epinephrine, and norepinephrine were added to pooled sera at catecholamine concentrations consistent with clinically relevant dosing. Creatinine was measured enzymatically on the Roche P-Modular, Ortho Clinical Diagnostics Vitros 350, and Abbott i-STAT. Jaffe methods were performed on the Roche P-Modular and Siemens Dimension RxL. In 10 patients receiving dopamine and/or dobutamine via a venous or arterial line we evaluated and compared the extent of in vivo creatinine interference in paired serum samples obtained by venipuncture and from indwelling catheters. Results: All catecholamines caused significant negative interference with the Roche enzymatic creatinine assay, most pronounced for dopamine and dobutamine. The Vitros enzymatic assay demonstrated slight negative interferences, and i-STAT enzymatic and Jaffe methods were unaffected by the presence of catecholamines. Significant (P < 0.001) differences in creatinine concentrations by Roche enzymatic vs Jaffe methods were observed in venipuncture specimens compared with arterial or venous catheter specimens, suggesting dopamine and dobutamine reversibly adhere to the catheter lumen. Conclusions: Negative interferences were pronounced for Roche enzymatic results in blood samples obtained from indwelling catheters, a phenomenon not observed in peripheral draws. Physicians and laboratorians should be alert to the possibility of a falsely low creatinine result and reevaluate questionable samples using a method unaffected by catecholamines.Keywords
Funding Information
- Siemens
- Siemens
This publication has 8 references indexed in Scilit:
- Recommendations for Improving Serum Creatinine Measurement: A Report from the Laboratory Working Group of the National Kidney Disease Education ProgramClinical Chemistry, 2006
- Effect of a compensated Jaffé creatinine method on the estimation of glomerular filtration rateAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2004
- Mechanisms of dopamine and dobutamine interference in biochemical tests that use peroxide and peroxidase to generate chromophoreClinical Chemistry, 1998
- Influence of dopamine on peroxidase-based assaysClinical Chemistry, 1996
- “Bouncing” Creatinine LevelsNew England Journal of Medicine, 1996
- Correction of Glucose Concentration Interference on Jaffé Kinetic Creatinine Assay in Peritoneal DialysisAmerican Journal of Nephrology, 1995
- PROBLEMS WITH THERAPEUTIC MONITORING OF CYCLOSPORINE USING SILICONE CENTRAL VENOUS LINE SAMPLESTransplantation, 1991
- Jaffes' reaction for creatinine: kinetic study and spectrophotometric characteristics of the product of the reactions of creatinine, acetoacetate and creatinine and acetoacetate with alkaline picrateBiochemical Society Transactions, 1988