Isotope ratio determination in boron analysis
Authors:
- 5 December 1998
- journal article
- review article
- Published by Springer Nature in Biological Trace Element Research
- Vol. 66 (1-3) , 39-53
Abstract
Traditionally, boron (B) isotope ratios have been determined using thermal ionization mass spectrometry (TIMS) and, to some extent, secondary ion mass spectrometry (SIMS). Both TIMS and SIMS use a high-resolution mass analyzer, but differ in analyte ionization methods. TIMS uses electrons from a hot filament, whereas SIMS employs an energetic primary ion beam of Ga+, Cs+, or O- for analyte ionization. TIMS can be used in negative or positive ion modes with high sensitivity and precision of B isotope ratio determination. However, isobaric interferences may be a problem, if the sample is not well purified and/or memory of the previous sample is not removed. Time-consuming sample preparation, analyte (B) purification, and sample determination processes limit the applications of TIMS for routine analyses. SIMS can determine B and its isotope ratio in intact solid samples without destroying them, but has poorer resolution and sensitivity than TIMS, and is difficult to standardize for biological samples. Development of plasma-source mass spectrometry (MS) enabled the determination of B concentration and isotope ratio without requiring sample purification. Commonly used plasmasource MS uses an Ar inductively coupled plasma (ICP) as an ionization device interfaced to a low-resolution quadrupole mass analyzer. The quadrupole ICP-MS is less precise than TIMS and SIMS, but is a popular method for B isotope ratio determination because of its speed and convenience. B determination by ICP-MS suffers no spectroscopic interferences. However, sample matrices, memory effects, and some instrument parameters may affect the accuracy and precision of B isotope ratio determination if adequate precautions are not taken. New generations of plasma-source MS instruments using highresolution mass analyzers provide better sensitivity and precision than the currently used quadrupole ICP-MS. Because of the convenience and high sample throughput, the high-resolution ICP-MS is expected to be the method of choice for B isotope ratio determination. The current state of instrumental capabilities is adequate for B isotope determination. However, precision and accuracy are primarily limited by sample preparation, introduction, and analytical methodology, including Analyte loss and isotope fractionation during sample preparation. The precision of B isotope determination in small samples, especially those containing low concentrations. Difficult matrices. Memory effects. Sample preparation by alkali fusion allows rapid and complete decomposition of hard-to-digest samples, but high-salt environments of the fused materials require extensive sample purification for B ratio determination. The alternative wet-ashing sample decomposition with HF also results in B loss and isotopic fractionation owing to the high volatility of BF3. Openvessel dryor wet-ashing methods usually do not work well for animal samples, and are also prone to B loss and contamination. Closed-vessel microwave digestion overcomes these problems, but the digests of biological materials have high C contents, which cause spectral interference on11B and affect11B/10 B ratios. Exchange separation/preconcentration of B using exchange (cation or anion exchange, B-specific resin, e.g., Amberlite IRA743) tend to cause B isotope fractionation, and C eluting from these resin columns may interfere with B isotope ratio determination. Memory effects of B that occur during sample determination may cause serious errors in B isotope ratio determination, especially when samples varying in B concentrations and/or isotope composition are analyzed together. Although the utilization of high-resolution plasma-source MS will undoubtedly improve analytical precision, it is the sample preparation, sample introduction, and analytical methodology that represent the primary limitation to accurate and precise B isotope ratio determination.Keywords
This publication has 49 references indexed in Scilit:
- Parameters influencing the calcination of plant materials in muffle furnaces and their importance for micronutrient analysisCommunications in Soil Science and Plant Analysis, 1996
- Measurement of boron isotope ratios in groundwater studiesThe Analyst, 1995
- Boron Isotope Application for Tracing Sources of Contamination in GroundwaterEnvironmental Science & Technology, 1994
- Determination of nanogram levels of boron in milligram-sized tissue samples by inductively coupled plasma-atomic emission spectroscopyAnalytica Chimica Acta, 1992
- Determination of boron in high-purity silica using direct current plasma emission spectrometryAnalytica Chimica Acta, 1991
- Measurement of boron concentration and isotope ratios in biological samples by inductivey coupled plasma mass spectrometry with direct injection nebulizationAnalytica Chimica Acta, 1991
- Suppression of boron volatilization from a hydrofluoric acid solution using a boron-mannitol complexAnalytical Chemistry, 1990
- A critical evaluation of the available measurements for the stable isotopes of boronApplied Geochemistry, 1990
- Extraction of boron from GSJ rock reference samples and determination of their boron isotopic ratiosAnalytica Chimica Acta, 1990
- An improved method for the high-precision isotopic measurement of boron by thermal ionization mass spectrometryInternational Journal of Mass Spectrometry and Ion Processes, 1988